Subsecond and in Situ Chemical Speciation of Pt/Al2O3 during Oxidation Reduction Cycles Monitored by High-Energy Resolution Off-Resonant X-ray Spectroscopy
Graph Chatbot
Chat with Graph Search
Ask any question about EPFL courses, lectures, exercises, research, news, etc. or try the example questions below.
DISCLAIMER: The Graph Chatbot is not programmed to provide explicit or categorical answers to your questions. Rather, it transforms your questions into API requests that are distributed across the various IT services officially administered by EPFL. Its purpose is solely to collect and recommend relevant references to content that you can explore to help you answer your questions.
Lipid membranes were studied by infrared scanning near-field optical microscopy at several wavelengths and by x-ray reflectivity. Together with the x-ray data, the optical images indicate the formation of locally ordered multiple bilayers, and the topograp ...
Ni-based catalysts are prone to deactivation (poisoning) of their active surface sites by sulphur and carbon species contained in the gas fed to the reactor. This study focuses on Ni/Al2O3-based catalyst samples which had allegedly been deactivated by sulp ...
An X-ray optical transmission grating of a focus-detector arrangement of an X-ray apparatus is disclosed, for generating projective or tomographic phase contrast recordings of a subject. In at least one embodiment, the grating includes a multiplicity of gr ...
12-Metallacrown-3 complexes were formed by self-assembly of organometallic half-sandwich complexes [(π-ligand)MCl2]2 (M = Ru, Rh, Ir) and 3-hydroxy-2-pyridone ligands in the presence of Cs2CO3 as base. Upon mixing of different macrocycles, reversible metal ...
The authors present a new technique to record single x-ray pulses in time-resolved x-ray absorption spectra spectroscopy (XAS) expts. at low frequencies around 1 kHz compared to the multibunch repetition rate at synchrotron radiation storage rings of sever ...
A pulse height analysis (PHA) x-ray system has been successfully implemented on the tokamak TCV, aiming at a low cost monitor system of the plasma electron temperature and impurity content. To meet the need for high throughput and fast acquisition, mandato ...
Several new results and opportunities for ultrafast x-ray absorption spectroscopy (XAS) are demonstrated. It is possible to work with highly dil. solns. in transmission mode without dramatic loss of signal-to-noise ratio. This is very promising as one can ...
The reaction of half-sandwich complexes of ruthenium, rhodium, and iridium with amino-substituted 3-hydroxy-2-pyridone ligands in aqueous solution gives monomeric O,O'-chelate complexes. Upon addition of base, the complexes assemble to form trimeric metall ...