Benefit of Cup Medialization in Total Hip Arthroplasty is Associated With Femoral Anatomy
Graph Chatbot
Chat with Graph Search
Ask any question about EPFL courses, lectures, exercises, research, news, etc. or try the example questions below.
DISCLAIMER: The Graph Chatbot is not programmed to provide explicit or categorical answers to your questions. Rather, it transforms your questions into API requests that are distributed across the various IT services officially administered by EPFL. Its purpose is solely to collect and recommend relevant references to content that you can explore to help you answer your questions.
The introduction of modular design in total hip arthroplasty has enabled the use of different materials in one single configuration and the adjustment of the prosthesis to the patient's body, and facilitated medical revisions. However, modularity leads to ...
BackgroundTotal knee arthroplasty (TKA) is most frequently planned using conventional two-dimensional weight-bearing lower limb radiographs and is performed with conventional femoral and tibial cutting guides. Questions have been raised about the accuracy ...
Glenohumeral osteoarthritis is a degenerative shoulder joint disease, which causes the breakdown of articular cartilage and bone. People affected by this disease suffer from severe pain and eventually reduced mobility and poor life quality. This disease is ...
The primary hypothesis of this study was that the survival rate over 10 years of total knee arthroplasties (TKAs) implanted with a navigation system was superior to that of TKAs implanted with a conventional technique. The secondary hypothesis was that the ...
Objective: To investigate (i) typical protocols used in research on biomechanical response to running-induced fatigue, (ii) the effect of sport-induced acute fatigue on the biomechanics of running and functional tests, and (iii) the consistency of analyzed ...
We report the successful acquisition of surface electromyography (sEMG) signals from an intelligent armband and its application in localized muscle fatigue monitoring with a costume-designed, small-scale front-end readout circuitry. The correlation coeffic ...
Background: Falls are a major cause of injuries in older adults. To evaluate the risk of falls in older adults, clinical assessments such as the 5-time sit-to-stand (5xSTS) test can be performed. The development of inertial measurement units (IMUs) has pro ...
In this paper, we report on the comprehensive study on Molybdenum disulfide (MoS2) nanolayer coated etched Fiber Bragg Grating (eFBG) strain sensor. MoS2 nanolayer is coated using Physical Vapor Deposition (PVD) of Molybdenum (Mo) on eFBGs followed by sulf ...
Background: Often used for T1 mapping of hip cartilage, three-dimensional (3D) dual-flip-angle (DFA) techniques are highly sensitive to flip angle variations related to B-1 inhomogeneities. The authors hypothesized that 3D magnetization-prepared 2 rapid gr ...
To overcome the multipath interference in locating transient electromagnetic (EM) radiation sources in an indoor environment, we propose a criterion that calculates the correlation between back-propagated signals from observation points, to be used in EM t ...