Influence of spandrel modelling on the seismic assessment of existing masonry buildings
Graph Chatbot
Chat with Graph Search
Ask any question about EPFL courses, lectures, exercises, research, news, etc. or try the example questions below.
DISCLAIMER: The Graph Chatbot is not programmed to provide explicit or categorical answers to your questions. Rather, it transforms your questions into API requests that are distributed across the various IT services officially administered by EPFL. Its purpose is solely to collect and recommend relevant references to content that you can explore to help you answer your questions.
Capacity design is an important tool that enables controlled ductile response of structures when subjected to earthquakes. The need for specific capacity design requirements for walls coupled by deep coupling beams, however, is often overlooked and it is a ...
This paper evaluates the effectiveness of single and multi-mode nonlinear static procedures (NSPs) as well as the FEMA P58 simplified approach versus rigorous nonlinear response history analyses (NRHA) for estimating seismic demands of steel special moment ...
Examining the results of a large set of quasi-static cyclic tests on unreinforced masonry (URM) walls showed that the drift capacity of URM walls reduces with increasing wall size. Such a size effect is of concern since most wall tests were carried out on ...
Abstract Performance-based earthquake engineering necessitates the development of reliable nonlinear analysis models that are able to simulate the behavior of structures from the onset of damage through collapse. These models provide engineering demand par ...
This paper presents the results of a series of shake-table tests on a half-scale, four-storey building with reinforced concrete (RC) and unreinforced masonry (URM) walls. Due to the lack of reference tests, the seismic behaviour of such mixed structures is ...
One of the main causes of damages for wind-turbine power plants is lightning. Direct and indirect events, indeed, can produce damages and malfunctions of electrical and mechanical components. Concerning mechanical components, blades and bearings are the mo ...
In modern unreinforced masonry (URM) walls, the vertical piers are connected at the storey levels by reinforced concrete (RC) ring beams or RC slabs. Particularly, in the outer walls, the spandrel element also includes a masonry spandrel on top of the RC b ...
A series of seismic tests were conducted on a 1½-bay by 1½-story special steel moment-resisting frame subassembly from the onset of damage through incipient collapse. These tests were conducted using hybrid simulation with substructuring as a mean to demon ...
The paper presents the results of the evaluation of the seismic safety of the Ancien Hôpital de Sion, an important Swiss architectural heritage building, sited in the Canton of Valais, the region with the highest seismic hazard in Switzerland. Three-dimens ...
Currently, although several tools have been proposed for the numerical modelling of the pile-soil interface, there is not a well-established framework concerning the quantitative impact that different estimations of the mechanical properties of this settin ...