Ask any question about EPFL courses, lectures, exercises, research, news, etc. or try the example questions below.
DISCLAIMER: The Graph Chatbot is not programmed to provide explicit or categorical answers to your questions. Rather, it transforms your questions into API requests that are distributed across the various IT services officially administered by EPFL. Its purpose is solely to collect and recommend relevant references to content that you can explore to help you answer your questions.
Presented is a novel approach for enhancing the signal-to-noise ratio (SNR) of optical fibre distributed temperature sensors. The proposed method is based on cyclic codes and it can be implemented by high-power lasers, which are required for long-range app ...
The effect of electron irradiation-induced shrinking on glass nanocapillaries with diameters ranging from 75 to 14 nm was analyzed by measuring the conductance characteristics with and without DNA translocation. We have investigated nanocapillary shrinking ...
Short-TE MRS has been proposed recently as a method for the in vivo detection and quantification of gamma-aminobutyric acid (GABA) in the human brain at 3 T. In this study, we investigated the accuracy and reproducibility of short-TE MRS measurements of GA ...
In this paper, a polar code for the m-user multiple access channel (MAC) with binary inputs is constructed. In particular, Arıkan’s polarization technique applied individually to each user will polarize any m-user binary input MAC into a finite collection ...
Physical impairments like IQ imbalance and phase noise can cause significant degradation in the performance of wireless communication systems. In this paper, the joint effects of IQ imbalance and phase noise on OFDM systems are analyzed, and a compensation ...
In this paper, polar codes for the m-user multiple access channel (MAC) with binary inputs are constructed. It is shown that Arikan's polarization technique applied individually to each user transforms independent uses of an m-user binary input MAC into su ...
Institute of Electrical and Electronics Engineers2012
In this paper, polar codes for the m-user multiple access channel (MAC) with binary inputs are constructed. It is shown that Arıkan’s polarization technique applied individually to each user transforms independent uses of a m-user binary input MAC into suc ...
Institute of Electrical and Electronics Engineers2012
Lanthanide luminescent bioprobes (LLBs) are amongst the most sensitive luminescent probes because their excited states are long-lived, which allows time-resolved detection (TRD) of their luminescence, boosting the signal-to-noise ratio and the sensitivity; ...
Biosensors often require detecting infinitesimal amount of species, thus their readout must be improved for highest sensitivity and best Signal-to-Noise ratio. We will present a simulation tool for piezoresistive strain sensors, which takes into account no ...
The high molecular weight and low concentration of brain glycogen render its noninvasive quantification challenging. Therefore, the precision increase of the quantification by localized (13) C MR at 9.4 to 14.1 T was investigated. Signal-to-noise ratio inc ...