Capacity factorThe net capacity factor is the unitless ratio of actual electrical energy output over a given period of time to the theoretical maximum electrical energy output over that period. The theoretical maximum energy output of a given installation is defined as that due to its continuous operation at full nameplate capacity over the relevant period. The capacity factor can be calculated for any electricity producing installation, such as a fuel consuming power plant or one using renewable energy, such as wind or the sun.
Neumann boundary conditionIn mathematics, the Neumann (or second-type) boundary condition is a type of boundary condition, named after Carl Neumann. When imposed on an ordinary or a partial differential equation, the condition specifies the values of the derivative applied at the boundary of the domain. It is possible to describe the problem using other boundary conditions: a Dirichlet boundary condition specifies the values of the solution itself (as opposed to its derivative) on the boundary, whereas the Cauchy boundary condition, mixed boundary condition and Robin boundary condition are all different types of combinations of the Neumann and Dirichlet boundary conditions.
Whole-house fanA whole house fan is a type of fan, commonly venting into a building's attic, designed to circulate air in an entire home or building. The fan removes hot air from the building and draws in cooler outdoor air through windows and other openings. While sometimes referred to as an "attic fan", this term properly refers to a powered attic ventilator, which exhausts hot air from the attic to the outside through an opening in the roof or gable at a low velocity.
Kalina cycleThe Kalina cycle, developed by Alexander Kalina, is a thermodynamic process for converting thermal energy into usable mechanical power. It uses a solution of 2 fluids with different boiling points for its working fluid. Since the solution boils over a range of temperatures as in distillation, more of the heat can be extracted from the source than with a pure working fluid. The same applies on the exhaust (condensing) end. This provides efficiency comparable to a Combined cycle, with less complexity.
Load factor (electrical)In electrical engineering the load factor is defined as the average load divided by the peak load in a specified time period. It is a measure of the utilization rate, or efficiency of electrical energy usage; a high load factor indicates that load is using the electric system more efficiently, whereas consumers or generators that underutilize the electric distribution will have a low load factor. An example, using a large commercial electrical bill: peak demand = 436kW use = 57200kWh number of days in billing cycle = 30day Hence: load factor = ( [ 57200kWh / {30day × 24h/d} ] / 436kW ) × 100% = 18.
Marketing managementMarketing management is the organizational discipline which focuses on the practical application of marketing orientation, techniques and methods inside enterprises and organizations and on the management of a firm's marketing resources and activities. Marketing management employs tools from economics and competitive strategy to analyze the industry context in which the firm operates. These include Porter's five forces, analysis of strategic groups of competitors, value chain analysis and others.