Publication

Pull-out behavior of CFRP ground anchors with two-strap ends

Abstract

Pull-out experiments were performed on three carbon fiber-reinforced polymer (CFRP) ground anchors simulating their applications in different rock types which provided different confinement levels. The CFRP tendons comprised, on the ground side, a prefabricated conical anchor body of high-strength grout in which two CFRP straps were embedded. The anchors reached an average load-bearing capacity of 1384 kN with final failure occurring in the CFRP straps. Grout failure was successfully prevented by an adequate grout selection and the installation of CFRP confinement rings to balance spreading forces at the strap ends. The confinement level provided by the surrounding media influenced the activation of the CFRP components in the anchor body by influencing the friction at the CFRP/grout interfaces. (C) 2017 Elsevier Ltd. All rights reserved.

About this result
This page is automatically generated and may contain information that is not correct, complete, up-to-date, or relevant to your search query. The same applies to every other page on this website. Please make sure to verify the information with EPFL's official sources.

Graph Chatbot

Chat with Graph Search

Ask any question about EPFL courses, lectures, exercises, research, news, etc. or try the example questions below.

DISCLAIMER: The Graph Chatbot is not programmed to provide explicit or categorical answers to your questions. Rather, it transforms your questions into API requests that are distributed across the various IT services officially administered by EPFL. Its purpose is solely to collect and recommend relevant references to content that you can explore to help you answer your questions.