Impedance-based real-time position sensor for lab-on-a-chip devices
Graph Chatbot
Chat with Graph Search
Ask any question about EPFL courses, lectures, exercises, research, news, etc. or try the example questions below.
DISCLAIMER: The Graph Chatbot is not programmed to provide explicit or categorical answers to your questions. Rather, it transforms your questions into API requests that are distributed across the various IT services officially administered by EPFL. Its purpose is solely to collect and recommend relevant references to content that you can explore to help you answer your questions.
Modern applications in industry, navigation and medicine demand small and sensitive magnetic field sensors. In this thesis we have developed a new planar micro fluxgate magnetometer. High resolution, low power consumption and orthogonal fields detection ma ...
This paper describes a microgripper used for the micro-assembly of an artificial scaffold for tissue engineering. The porous sponge-like scaffold is a three dimensional construct built by tiny unit parts of biodegradable polymer. This application requires ...
In this thesis, a new microfabricated flow cytometer for single cell discrimination based on dielectric spectroscopy is presented. Integrated tools for rapid in-flow cell handling are also demonstrated. Signal amplification and analysis as well as the chip ...
Two types of DNA biosensors are presented. Both sensing principles are demonstrated using synthetic oligomer single-stranded DNA (ssDNA) with concentrations in the micromolar range. A first sensor type is based on the detection of fluorescently labeled ssD ...
This article presents the first example of a microfluidic chip for heterogeneous bioassays using a locally immobilized biospecitic layer and operated electrokinetically. The reaction chamber has picoliter dimensions and is integrated into a network of micr ...
This thesis presents the fabrication and design of an impedance imaging sensor, and its application to monitoring in-vitro skin culture. Three-dimensional tissue cultures are becoming increasingly important in biological and medical research. There is, how ...
A new cytological tool, based on the micro Coulter particle counter (CPC) principle, aimed at diagnostic applications for cell counting and separation in haematology, oncology or toxicology is described. The device measures the spectral impedance of indivi ...
Vertical Hall sensors are capable of measuring surface-parallel components of the magnetic field. They allow therefore relatively easy conception of single-chip multi-axial magnetic sensors compared to solutions using horizontal Hall plates. The modern tre ...
A two-dimensional (2-D) array (4 by 8) of single-photon avalanche diodes integrated in an industrial complementary metal-oxide-semiconductor (CMOS) process is presented. Each pixel combines a photodiode biased above its breakdown voltage in the so-called G ...
This paper describes the design, fabrication and experimental results of a new, low cost, high-performance silicon micropump developed for a disposable drug delivery system. The pump chip demonstrates linear and accurate (+/-5%) pumping characteristics for ...