Are you an EPFL student looking for a semester project?
Work with us on data science and visualisation projects, and deploy your project as an app on top of Graph Search.
Nowadays, discomfort glare indices are frequently calculated by using evalglare. Due to the lack of knowledge on the implications of the methods and parameters of evalglare, the default settings are often used. But wrong parameter settings can lead to inappropriate glare source detection and therefore to invalid glare indices calculations and erroneous glare classifications. For that reason, this study aims to assess the influence of several glare source detection methods and parameters on the accuracy of discomfort glare prediction for daylight. This analysis uses two datasets, representative of the two types of discomfort glare: saturation and contrast glare. By computing three different statistical indicators to describe the accuracy of discomfort glare prediction, 63 different settings are compared. The results suggest that the choice of an evalglare method should be done when considering the type of glare that is most likely to occur in the visual scene: the task area method should be preferred for contrast glare scenes, and the threshold method for saturation glare scenes. The parameters that should be favored or avoided are also discussed, although a deeper understanding of the discomfort glare mechanism and a clear definition of a glare source would be necessary to reliably interpret these results.
Marilyne Andersen, Jan Wienold, Sneha Jain