Are you an EPFL student looking for a semester project?
Work with us on data science and visualisation projects, and deploy your project as an app on top of Graph Search.
This paper investigates the impact of transmittance level and layout variations of semi-transparent photovoltaics (STPV) on both energy performance and occupancy-based visual and thermal comfort, simulating a reference office with a fully south-oriented glazed surface. Four transmittance levels (20, 30, 40 and 50%) were investigated, first uniformly distributed on the full glazing (i.e., one specific transmittance for the entire glazing) and then considered in combination (i.e., with the glazing divided in equal-height bands with different transmittance levels). Simulations were conducted in three climatic conditions: temperate (Geneva), hot-arid (Casablanca) and cold (Helsinki). Following the proposed energy and occupancy-based visual and thermal comfort analysis, the best design option for both Geneva and Helsinki climate resulted the 2-level STPV design variation with 50% visible transmittance on top of the glazing. In Casablanca, the 1-level design variation with the lowest visible transmittance (20%) uniformly distributed resulted as the best choice. This work, besides offering a first exploration of the relationships between climatic context and STPV design variations, describes a spatial multi-criteria analysis method that could be applied for the evaluation of other glazing technologies.
Josef Andreas Schuler, Jérémy Jacques Antonin Fleury