DISCLAIMER: The Graph Chatbot is not programmed to provide explicit or categorical answers to your questions. Rather, it transforms your questions into API requests that are distributed across the various IT services officially administered by EPFL. Its purpose is solely to collect and recommend relevant references to content that you can explore to help you answer your questions.
This paper describes the development of an analytical technique for arsenic analyses that is based on genetically-modified bioreporter bacteria bearing a gene encoding for the production of a green fluorescent protein (gfp). Upon exposure to arsenic (in th ...
The past few years we have witnessed a tremendous surge of interest in so-called array-based miniaturised analytical systems due to their value as extremely powerful tools for high-throughput sequence analysis, drug discovery and development, and diagnosti ...
The use of a fluorescent marker 1,1,4,4-tetraphenyl-1,3-butadiene (I) in detg. the axial mixing in fluidization is studied. I was adsorbed by SiO2 gel (sieve fraction 0.1-0.125 mm). The SiO2 gel of the fluidized bed was a sieve fraction of 0.1-0.15 mm. The ...
An optical method based on fluorescence spectroscopy was developed for in-situ non-destructive, real time, org. pollutant detection and quantification in soil. Optical fiber-based light-induced fluorescence probes allowing in-situ specific chem. detection ...
To improve the detectability of tumors by light-induced fluorescence, the use of monoclonal antibodies (MoAb) as carriers of fluorescent molecules was studied. As a model for this approach, the biodistribution of an anticarcinoembryonic antigen (CEA) MoAb ...
Micro-optical systems based on refractive microlenses are investigated. These systems are integrated on a chemical chip. They focus an excitation beam into the detection volume (microliter or even submicroliter scale) and collect the emitted light from flu ...
Micro-optical systems based on refractive microlenses are investigated. These systems are integrated on a chemical chip. They focus an excitation beam into the detection volume (microliter or even submicroliter scale) and collect the emitted light from flu ...
We describe the design and performance tested during six years of clinical trials of a fluorescence endoscope for the detection and delineation of cancers in several hollow organs. The apparatus is based on the imaging of the laser-induced fluorescence tha ...
The invention relates to a method and a device for sequencing nucleic acid mols. on a perforated membrane. The inventive method and device can be esp. used in multiplex sequencing. The method involves prepg. an oligonucleotide that is labeled to satn. with ...