Fire endurance of multicellular panels in an FRP building system
Related publications (69)
Graph Chatbot
Chat with Graph Search
Ask any question about EPFL courses, lectures, exercises, research, news, etc. or try the example questions below.
DISCLAIMER: The Graph Chatbot is not programmed to provide explicit or categorical answers to your questions. Rather, it transforms your questions into API requests that are distributed across the various IT services officially administered by EPFL. Its purpose is solely to collect and recommend relevant references to content that you can explore to help you answer your questions.
As the range of applications for fiber-reinforced polymer (FRP) composite materials in civil engineering constantly increases, there is more and more concern with regard to their performance in critical environments. The fire behavior of composite material ...
3D stacked circuits reduce communication delay in multicore system-on-chips (SoCs) and enable heterogeneous integration of cores, memories, sensors, and RF devices. However, vertical integration of layers exacerbates the reliability and thermal problems, a ...
Novel cooling systems with very low material budget are being fabricated and studied. They consist of silicon wafers in which microchannels are etched and closed by bonding another wafer. This cooling option is being considered for future HEP detectors of ...
A recently developed thermomechanical model to predict the time-dependent thermal and mechanical responses of pultruded glass fiber-reinforced polymer (GFRP) profiles subjected to fire was extended to include the beneficial effects of passive fire protecti ...
Microcellular Al-4.5 wt pct Cu of 400- or 75-mu m average pore diameter is solidified at cooling rates ranging from -30 K/min to -0.45 K/min (-30 A degrees C/min to -0.45 A degrees C/min). In the 400-mu m pore size samples, the dendritic character is lost, ...
This paper presents results of experimental investigations on the behaviour of GFRP pultruded profiles exposed to fire, in order to study the viability of their structural use in floors of buildings, taking into account the fulfilment of fire resistance re ...
An active fire protection system, liquid-cooling, was applied to pultruded GFRP tubes subjected to combined thermal and mechanical loading in order to maintain material temperature below the critical glass transition temperature. The use of an appropriate ...
Structural fire endurance experiments were conducted on full-scale cellular glass fiber reinforced (GFRP) columns under axial compression and subjected to ISO 834 fire exposure from one side. Unprotected columns could resist fire for more than 30 min, whic ...
Springer-Verlag New York, Ms Ingrid Cunningham, 175 Fifth Ave, New York, Ny 10010 Usa2010
Liquid cooling has emerged as a promising solution for addressing the elevated temperatures in 3D stacked architectures. In this work, we first propose a framework for detailed thermal modeling of the microchannels embedded between the tiers of the 3D syst ...
Experimental results on the fire endurance of full-scale glass fiber-reinforced polymer (GFRP) composite columns are reported in this paper. The pultruded four-cell profiles were first loaded to axial compression (uniform serviceability stress of 5 MPa) an ...