Connexions par adhérence pour les ponts mixtes acier-béton
Graph Chatbot
Chat with Graph Search
Ask any question about EPFL courses, lectures, exercises, research, news, etc. or try the example questions below.
DISCLAIMER: The Graph Chatbot is not programmed to provide explicit or categorical answers to your questions. Rather, it transforms your questions into API requests that are distributed across the various IT services officially administered by EPFL. Its purpose is solely to collect and recommend relevant references to content that you can explore to help you answer your questions.
Reinforced concrete slabs without shear reinforcement under concentrated loads near linear supports are typical cases of bridge deck slabs, transfer slabs or pile caps. Such members are often designed or assessed in shear/punching shear with code provision ...
This paper deals with of a new type of steel-concrete connection for composite beams. The connection is an alternative solution for steel-concrete composite bridges suitable for prefabrication and fast erection. The composite action of the beam is establis ...
Extended shear tab connections are widely used to connect beams to the webs of girders. In the full-depth configuration of extended beam-to-girder shear tabs, the shear plate is typically fillet welded to the web, as well as to the top and bottom flanges o ...
The presence of damage in a railway bridge alters its stiffness and consequently, its static and dynamic response to loading. The dynamic response of a railway bridge to loading produces a dynamic response in the passing vehicle, potentially enabling detec ...
Nonlinear dynamic (response history) analysis is being used increasingly in design practice for the performance-based seismic design of new buildings. In contrast to nonlinear static analysis, dynamic analysis requires more explicit modeling of cyclic resp ...
A novel monitoring scheme oriented towards the structural examination of reinforced concrete slabs subject to railway traffic action is presented. Monitoring is based on the measurement of the mean axial strain profile variation in the cross-section of the ...
By reviewing some of the reinforced-concrete structures built in the early 20th century, this paper questions the geometrical aspects surrounding their design. It is well established that in the case of Robert Maillart’s designs, he relied on the logic of ...
This paper presents a study of a system of post-tensioned structural glass beams. In order to increase the initial fracture strength of glass beams and provide residual load-carrying capacity in the event of glass failure, annealed laminated glass beams ar ...
This paper discusses the findings of an experimental program that was conducted to investigate the behaviour of extended shear tab beam-to-column and beam-to-girder connections that are commonly used in North America. The laboratory results showed that ext ...
The punching shear strength of interior column connections of flat slabs has traditionally been investigated with isolated test specimens subjected exclusively to hogging bending moments. However, the behavior of such specimens is different from that of ac ...