DISCLAIMER: The Graph Chatbot is not programmed to provide explicit or categorical answers to your questions. Rather, it transforms your questions into API requests that are distributed across the various IT services officially administered by EPFL. Its purpose is solely to collect and recommend relevant references to content that you can explore to help you answer your questions.
Single-phase active rectifiers exhibit an inherent strong second-order current harmonic on their DC-link. The latter is often undesirable from a load point of view and is therefore chosen to be eliminated. A common method is the use of a resonant passive L ...
Nowadays, several state-of-the-art multilevel converter topologies are used for numerous industrial medium-voltage (MV) high-power variable-speed drive applications. The 3-level neutral point clamped (3L-NPC) topology is one of those and is often used as a ...
The management of voltage and reactive power control sources considering the voltage stability is a challenging issue for secure operation of power systems. Generally the analysis of the stability margin is performed using P V and V Q based approaches. Thi ...
This paper studies the multi-area voltage and reactive power management regarding the voltage stability. In this respect, the maximization of effective reactive power reserve is proposed using centralized and decentralized implementations. The proposed for ...
Nowadays, several state-of-the-art multilevel converter topologies are used for numerous industrial medium-voltage (MV) high-power variable-speed drive applications. The 3-level neutral point clamped (3L-NPC) topology is one of those and is often used as a ...
Voltage stability imposes important limitations on the power systems operation. Adequate voltage stability margin needs to be obtained through the appropriate scheduling of the reactive power resources. The main countermeasures against voltage instability ...
In electrical systems, the small-signal stability analysis method is usually applied to synchronous machines by using the Park representation (d, q-components). This paper presents the generalization of a different approach for this method, based on a, b, ...
Low system voltage in traction networks, mainly caused by active power absorption of locomotives, adversely affects the performance of the locomotives and also the power transmission capability of the catenary line. This paper introduces a voltage support ...
This paper proposes a voltage support scheme for traction networks, which compensates for the voltage drop along the catenary line to which locomotives are connected. The proposed method is based on the injection of capacitive reactive power through the cu ...
This paper aims at proving the application of the fault location method based on the Electromagnetic Time Reversal (EMTR) to multi-terminal HVDC (MTDC) networks. In particular, the paper integrates the EMTR fault location technique with the protection sche ...