Posez n’importe quelle question sur les cours, conférences, exercices, recherches, actualités, etc. de l’EPFL ou essayez les exemples de questions ci-dessous.
AVERTISSEMENT : Le chatbot Graph n'est pas programmé pour fournir des réponses explicites ou catégoriques à vos questions. Il transforme plutôt vos questions en demandes API qui sont distribuées aux différents services informatiques officiellement administrés par l'EPFL. Son but est uniquement de collecter et de recommander des références pertinentes à des contenus que vous pouvez explorer pour vous aider à répondre à vos questions.
Intube flow boiling experiments for refrigerant R-134a mixed with a lubricating oil are reported for a plain, horizontal tube. The tests were run at a nominal inlet pressure of 3.4 bar over a wide range of vapor qualities at mass velocities of 100, 200, an ...
This review highlights the major advantages and challenges of mechanically driven heat pumps and refrigeration systems with focus on multi-temperature applications. Different design strategies are presented, including cycles with multi-stage compressors, e ...
The capacities of performance improvements of low and mid-size heat pumps are studied in this project. For the new buildings market, the components of the heat pump match already well the requirements for high performance and monovalent heating. Minor impr ...
Olefins Plants show an intrinsic cost of the energy demand which derives from Process and Plant design. Few innovative changes have been implemented in the past decades. Such changes were mainly directed to increasing the throughput of the plant and its fl ...
This study is a contribution for the improvement of horizontal falling film heat exchangers. This type of evaporator has the potential to be widely used in the petrochemical industry, for the sea water desalination, or in the large refrigeration systems. A ...
As part of a comprehensive study on factors affecting flow boiling in horizontal tubes, local boiling heat transfer coefficients were measured for R- 134a evaporating inside the same 12.00 mm bore, plain tube for horizontal flow, vertical upflow and vertic ...
Intube flow boiling experiments for refrigerant R-134a mixed with a lubricating oil are reported. The tests were run at a nominal inlet pressure of 3.4 bar over a wide range of vapor qualities at mass velocities of 100, 200 and 300 kg/m2s (73500, 147000 an ...
An improved two-phase flow pattern map is proposed for evaporation in horizontal tubes. Based on new flow pattern data for three different refrigerants covering a wide range of mass velocities, vapor qualities and heat fluxes. The new flow pattern map incl ...