External fixation is a surgical treatment wherein Kirschner pins and wires are inserted and affixed into bone and then exit the body to be attached to an external apparatus composed of rings and threaded rods — the Ilizarov apparatus, the Taylor Spatial Frame, and the Octopod External Fixator — which immobilises the damaged limb to facilitate healing. As an alternative to internal fixation, wherein bone-stabilising mechanical components are surgically emplaced in the body of the patient, external fixation is used to stabilize bone tissues and soft tissues at a distance from the site of the injury.
In Classical Greece, the physician Hippocrates described an external fixation apparatus composed of leather rings connected with four wooden rods from a Cornel tree to splint the fracture of a tibia bone.
In 1840, Jean-Francois Malgaigne described a spike driven into the tibia and held by straps to immobilise a fractured tibia. In 1843 he used a claw-like device to percutaneously hold the fragments of a fractured patella.
Clayton Parkhill of Denver, Colorado and Albine Lambotte of Antwerp, Belgium independently invented the modern concept of unilateral external fixation, in 1894 and 1902, respectively. Lambotte was the first to use threaded pins, however, his device necessitated initial, open fracture reduction and then pin insertion and fixator placement.
In 1938, Raoul Hoffmann of Geneva, Switzerland, building on the work of others, realized that major improvements were essential to make the external fixator more clinically relevant. He developed a technique based on closed reduction with guided percutaneous pin placement. Hoffmann’s technique exemplified the first application of minimally invasive orthopaedic surgery.
In the 1950s, in the USSR, Dr. Gavriil Ilizarov devised and developed and applied the Ilizarov apparatus for treating and resolving fractures, deformities, and defects of the bones of the limbs. A metal frame encircles the limb is attached to the underlying bone by crossing (X) pins inserted through the bone and limb.
Cette page est générée automatiquement et peut contenir des informations qui ne sont pas correctes, complètes, à jour ou pertinentes par rapport à votre recherche. Il en va de même pour toutes les autres pages de ce site. Veillez à vérifier les informations auprès des sources officielles de l'EPFL.
A distal radius fracture, also known as wrist fracture, is a break of the part of the radius bone which is close to the wrist. Symptoms include pain, bruising, and rapid-onset swelling. The ulna bone may also be broken. In younger people, these fractures typically occur during sports or a motor vehicle collision. In older people, the most common cause is falling on an outstretched hand. Specific types include Colles, Smith, Barton, and Chauffeur's fractures. The diagnosis is generally suspected based on symptoms and confirmed with X-rays.
In medicine, the Ilizarov apparatus is a type of external fixation apparatus used in orthopedic surgery to lengthen or to reshape the damaged bones of an arm or a leg; used as a limb-sparing technique for treating complex fractures and open bone fractures; and used to treat an infected non-union of bones, which cannot be surgically resolved. The Ilizarov apparatus corrects angular deformity in a leg, corrects differences in the lengths of the legs of the patient, and resolves osteopathic non-unions; further developments of the Ilizarov apparatus progressed to the development of the Taylor Spatial Frame.
Une fracture (Fx) est une rupture partielle ou complète d'un os. Dans les cas plus graves, l'os peut être cassé en plusieurs morceaux. Les premiers éléments pouvant faire penser à une fracture sont : le mécanisme : choc, chute ; la douleur, soudaine et localisée ; l'impotence fonctionnelle : il est douloureux ou impossible d'effectuer certains mouvements ; la déformation : formation d'un œdème (gonflement), angulation du membre (fracture avec déplacement), enfoncement ; la présence possible d'un hématome.
Explore la conception d'implants orthopédiques, en mettant l'accent sur l'amélioration de la fixation dans les os de mauvaise qualité et en discutant des tendances futures dans les projets de biomatériaux.
Explore la modélisation de la réponse aux chocs des matériaux fragiles, y compris l'évaluation de la résistance à l'écaillage et les mécanismes de rupture par cisaillement.
Geo-energy is a comprehensive term used to describe any form of energy that comes from the Earth. This includes hydrocarbons such as gas, oil, and coal, but also geothermal energy (shallow and deep). The focus of this thesis is on Enhanced Geothermal Syste ...
2020
, ,
Deep heat mining requires activation of slip on pre-existing geological discontinuities and the creation of hydraulically conductive fracture networks. Fluid injection or diffusion of ground waters can rise the fluid pressure near pre-existing fractures an ...
2023
,
The emplacement of magmatic intrusions in the earth’s crust has been investigated for decades. The driving mechanism is the density difference between the fluid and the rock. In the absence of heterogeneities, this difference creates a constant buoyancy fo ...