AVERTISSEMENT : Le chatbot Graph n'est pas programmé pour fournir des réponses explicites ou catégoriques à vos questions. Il transforme plutôt vos questions en demandes API qui sont distribuées aux différents services informatiques officiellement administrés par l'EPFL. Son but est uniquement de collecter et de recommander des références pertinentes à des contenus que vous pouvez explorer pour vous aider à répondre à vos questions.
Among the various logical components of a phasor measurement unit (PMU), the synchrophasor estimation (SE) algorithm definitely represents the core one. Its choice is driven by two main factors: its accuracy in steady state and dynamic conditions as well a ...
The Institution of Engineering and Technology - IET2015
The calibration of Phasor Measurement Units (PMUs) consists of comparing Coordinated Universal Time (UTC) time-stamped phasors (synchrophasors) estimated by the PMU under test, against reference synchrophasors generated through a PMU calibrator. The IEEE S ...
Wind is a variable and uncontrollable source of power with a low capacity factor. Using energy storage facilities with a non-firm connection strategy is the key to maximum integration of distant wind farms into a transmission-constrained power system. In t ...
Power system dynamic simulators can be classified according to multiple criteria, including speed, precision, cost and modularity (topology, characteristics and model). Existing simulators are based on time-consuming numeric algorithms, which provide very ...
The field of application of Phasor Measurement Units (PMUs) might be limited by the PMU measurements reporting latencies and achievable reporting rates, particularly with respect to power system protection applications that typically require very low laten ...
The field of application of Phasor Measurement Units (PMUs) might be limited by the PMU measurements reporting latencies and achievable reporting rates, particularly with respect to power system protection applications that typically require very low laten ...
IEEE C37.118 is the current standard for synchrophasor measurements in power systems. It defines the measurement method and communication protocols for the entities in a synchrophasor network. The standard offers two different modes for client-server commu ...
Modern society is dependent on reliable electricity for security, health, communication, transportation, finance, computers and nearly all aspects of the contemporary life. Providing reliable electricity is a very complex challenge. It involves real-time m ...
The accurate measurement of synchrophasors in static and dynamic power network conditions represents one of the main requirements of Phasor Measurement Units (PMUs). International Standards (i.e. the IEEE C37.118) are quickly evolving to drive the technolo ...
This paper aims to assess the performance of linear state estimation (SE) processes of power systems relying on synchrophasor measurements. The performance assessment is conducted with respect to two different families of SE algorithms, i.e., static ones r ...
Institute of Electrical and Electronics Engineers2016