Posez n’importe quelle question sur les cours, conférences, exercices, recherches, actualités, etc. de l’EPFL ou essayez les exemples de questions ci-dessous.
AVERTISSEMENT : Le chatbot Graph n'est pas programmé pour fournir des réponses explicites ou catégoriques à vos questions. Il transforme plutôt vos questions en demandes API qui sont distribuées aux différents services informatiques officiellement administrés par l'EPFL. Son but est uniquement de collecter et de recommander des références pertinentes à des contenus que vous pouvez explorer pour vous aider à répondre à vos questions.
The core–shell structure of a range of acrylic–acrylic latexes has been investigated by combining different specimen preparation methods with transmission electron microscopy (TEM), dark-field scanning transmission electron microscopy (DSTEM) and low-volta ...
Electron crystallography of membrane proteins determines the structure of membrane-reconstituted and two-dimensionally (2D) crystallized membrane proteins by low-dose imaging with the transmission electron microscope, and computer image processing. We have ...
A large number of characterization tools for semiconductor based heterostructures are available nowadays. Most of these techniques deliver high temporal resolution (down to hundreds of femtoseconds) or good spatial resolution (down to sub nanometer resolut ...
In-situ materials tests have the advantage to link visual and sensor based information during a dynamic experiment. In this thesis, a compact indenter-scratch test device has been built at EPFL-LSRO and installed inside a Scanning Electron Microscope (SEM) ...
The electron beam induced current (EBIC) technique was used to characterize a 32 μm thick hydrogenated amorphous silicon n-i-p diode deposited on top of an ASIC, containing several channels of active feedback pre-amplifiers (AFP) with peaking time of 5 ns. ...
The fracture strength of ZnO nanowires vertically grown on sapphire substrates was measured in tensile and bending experiments. Nanowires with diameters between 60 and 310 nm and a typical length of 2 μm were manipulated with an atomic force microscopy tip ...
The aim of this study is to develop coatings on polymer substrates with a combined increase in oxygen barrier performance and toughness, based on SiOx coatings modified with multifunctional organo-silane polymers of controlled polarity and reactivity. As a ...
The core–shell structure of a range of acrylic–acrylic latexes has been investigated by combining different specimen preparation methods with transmission electron microscopy (TEM), dark-field scanning transmission electron microscopy (DSTEM) and low-volta ...
Ferritic/martensitic (F/M) steels show good resistance to swelling and low damage accumulation upon irradiation relative to stainless steels. 0.3 wt% yttria particles were added to the F/M steel EUROFER 97 to produce oxide dispersion strengthened (ODS) ste ...
The growth dynamics of oxygen assisted focused electron beam induced deposition of Si-containing materials (from SiOxCy to SiO2) were investigated as a function of relevant process parameters. The results obtained from organosilanes of different families ( ...