AVERTISSEMENT : Le chatbot Graph n'est pas programmé pour fournir des réponses explicites ou catégoriques à vos questions. Il transforme plutôt vos questions en demandes API qui sont distribuées aux différents services informatiques officiellement administrés par l'EPFL. Son but est uniquement de collecter et de recommander des références pertinentes à des contenus que vous pouvez explorer pour vous aider à répondre à vos questions.
Surface treatment optimization requires the control of the ion dose and the workpiece temperature, two parameters that are not trivially measurable in plasma-based ion implantation. A temperature and ion fluence monitoring system has been developed and imp ...
We have experimentally studied the effects of gamma-radiation up to very high total doses on the physical properties of Brillouin scattering in standard commercially available optical fibres. A frequency variation of about 5 MHz for both Brillouin frequenc ...
Reported MOSFET measurements concern mostly external radiotherapy and in vivo dosimetry. In this paper, we apply the technique for absolute dosimetry in the context of HDR brachytherapy using an 192Ir source. Measured radial dose rate distributions in wate ...
To investigate the suitability of 144Ce for both interstitial and intravascular brachytherapy applications. Monte Carlo calculations of radial dose rate distributions in water were performed for 144Ce in a spring-shaped source and compared with two commonl ...
Radiation tests of 32 μm thick hydrogenated amorphous silicon n-i-p diodes have been performed using a high- energy 24 GeV proton beam up to fluences of 2x1016 protons/cm2. The results are compared to irradiation of similar 1 μm and 32 μm thick n-i-p diode ...
The use of spectrometry to provide information for neutron radiation protection has become an increasingly important activity over recent years. The need for spectral data arises because neither area survey instruments nor personal dosimeters give the corr ...
LiF:Mg,Cu,P phosphors (commercially designated as MCP-N) are very sensitive thermoluminescent detectors and are considered by many laboratories to hold great promise for low level radiation monitoring. It is their high efficiency relative to TLDs based on ...
Reduced activation martensitic steel specimens were irradiated by dual-beam from 0.1 to 50 dpa at 250 and 300 degreesC with 10 He appm/dpa. The in-situ microstructure observation shows that the bubbles were present after 1.7 dpa for 250 degreesC irradiatio ...
Segregation of P and Mo to prior austenite grain boundaries in a 2.25Cr1Mo steel subjected to neutron irradiation and ageing is examined using field emission gull scanning transmission electron microscopy (FEGSTEM) with energy dispersive X-ray microanalysi ...
Purpose: The present study was initiated to det. the conditions under which a single photodynamic treatment would induce maximal damage to a tumor with no or at least minimal reversible damage to a normal striated muscle. Methods and Materials: The techniq ...