Serum protein electrophoresisSerum protein electrophoresis (SPEP or SPE) is a laboratory test that examines specific proteins in the blood called globulins. The most common indications for a serum protein electrophoresis test are to diagnose or monitor multiple myeloma, a monoclonal gammopathy of uncertain significance (MGUS), or further investigate a discrepancy between a low albumin and a relatively high total protein. Unexplained bone pain, anemia, proteinuria, chronic kidney disease, and hypercalcemia are also signs of multiple myeloma, and indications for SPE.
Électrophorèse des protéinesL'électrophorèse des protéines (ou des protides) est une méthode d'analyse d'un mélange de protéines par une électrophorèse sur gel. Elle repose sur la capacité des protéines chargées à migrer au travers des pores d'un gel lorsqu'on applique un courant électrique. Elle est employée en protéomique ainsi qu'en médecine, principalement à partir de sérum sanguin (le plasma sanguin ne convient pas). L'électrophorèse est une technique chimique d'analyse des masses des molécules.
Électrophorèse sur gelalt=Appareil à électrophorèse sur gel d'agarose|vignette|Appareil pour électrophorèse d'ADN en gel d'agarose. Le gel est horizontal baigne dans le tampon qui remplit la cuve. L'ADN est déposé dans des puits à une extrémité du gel. L'alimentation en arrière-plan fournit la tension électrique continue qui permet la migration des fragments d'ADN dans le gel. L'électrophorèse sur gel est une variante de l'électrophorèse de zones.
Électrophorèse bidimensionnelleTwo-dimensional gel electrophoresis, abbreviated as 2-DE or 2-D electrophoresis, is a form of gel electrophoresis commonly used to analyze proteins. Mixtures of proteins are separated by two properties in two dimensions on 2D gels. 2-DE was first independently introduced by O'Farrell and Klose in 1975. 2-D electrophoresis begins with electrophoresis in the first dimension and then separates the molecules perpendicularly from the first to create an electropherogram in the second dimension.
Serum albuminSerum albumin, often referred to simply as blood albumin, is an albumin (a type of globular protein) found in vertebrate blood. Human serum albumin is encoded by the ALB gene. Other mammalian forms, such as bovine serum albumin, are chemically similar. Serum albumin is produced by the liver, occurs dissolved in blood plasma and is the most abundant blood protein in mammals. Albumin is essential for maintaining the oncotic pressure needed for proper distribution of body fluids between blood vessels and body tissues; without albumin, the high pressure in the blood vessels would force more fluids out into the tissues.
Human serum albuminHuman serum albumin is the serum albumin found in human blood. It is the most abundant protein in human blood plasma; it constitutes about half of serum protein. It is produced in the liver. It is soluble in water, and it is monomeric. Albumin transports hormones, fatty acids, and other compounds, buffers pH, and maintains oncotic pressure, among other functions. Albumin is synthesized in the liver as preproalbumin, which has an N-terminal peptide that is removed before the nascent protein is released from the rough endoplasmic reticulum.
Maîtrise de la demande en énergieLa notion de maîtrise de la demande en énergie (qui comprend celle de maîtrise de la demande en électricité) souvent dite MDE (en anglais, energy demand management (EDM), demand-side management (DSM) ou demand-side response (DSR)), regroupe des actions d'économies d'énergie développées du côté du consommateur final, et non du producteur d'énergie (bien que ce dernier puisse y contribuer). La MDE a été initiée dans les années 1990, aux États-Unis et en Europe principalement (dont en France avec le soutien de l'AFME devenue ADEME).
Load managementLoad management, also known as demand-side management (DSM), is the process of balancing the supply of electricity on the network with the electrical load by adjusting or controlling the load rather than the power station output. This can be achieved by direct intervention of the utility in real time, by the use of frequency sensitive relays triggering the circuit breakers (ripple control), by time clocks, or by using special tariffs to influence consumer behavior.