Posez n’importe quelle question sur les cours, conférences, exercices, recherches, actualités, etc. de l’EPFL ou essayez les exemples de questions ci-dessous.
AVERTISSEMENT : Le chatbot Graph n'est pas programmé pour fournir des réponses explicites ou catégoriques à vos questions. Il transforme plutôt vos questions en demandes API qui sont distribuées aux différents services informatiques officiellement administrés par l'EPFL. Son but est uniquement de collecter et de recommander des références pertinentes à des contenus que vous pouvez explorer pour vous aider à répondre à vos questions.
The vibrational spectrum of a tunneling junction on a clean Cu(111) surface has been characterized by vibrational density of states calculations and inelastic electron tunneling spectroscopy technique. We demonstrate that the achieved spectrum consists not ...
The optical properties of small size selected metal clusters have been studied by fluorescence spectroscopy. Cun (n = 1-5, 8), Agn (n = 1-5, 8, 9, 20), Aun (n = 1-5, 8) and Nin (n = 1-3) clusters embedded in condensed neon are photoionized by VUV photons i ...
The CLIC Test Facility 3 (CTF3) drive beam injector should provide high intensity and high quality electron beams. The present installation relies on a thermionic gun followed by a complexRF bunching system. As an upgrade to improve the beam emittance and ...
Using low-temperature scanning tunneling spectroscopy at 5 and 50 K, we studied the linewidth of unoccupied quantum-well states in ultrathin Pb islands, grown on Si(111) on two different Pb/Si interfaces. A quantitative analysis of the differential conduct ...
The formation of LiBD4 by the reaction of LiD in a diborane/hydrogen atmosphere was analysed by in situ neutron diffraction and subsequent microstructural and chemical analysis of the final product. The neutron diffraction shows that nucleation of LiBD4 al ...
During the past two decades instrumentation in scanning transmission electron microscopy (STEM) has pushed toward higher intensity electron probes to increase the signal-to-noise ratio of recorded images. While this is suitable for robust specimens, biolog ...
A different approach in microcolumn design is presented, aiming at a large number of pixels at minimal probe size for the deflected beam. An optimization routine resulted in a seven times magnifying column featuring a more than 7×7 mm2 scan field at 40 mm ...
We investigated the performance of Hall sensors with different Co-C ratios, deposited directly in nanostructured form, using Co-2(CO)(8) gas molecules, by focused-electron or ion-beam-induced deposition. Due to the enhanced intergrain scattering in these g ...
We report on the fabrication and characterization of high performance nanowire superconducting single photon detectors (SSPD) on MgO substrates. The deposition of the superconducting material (NbN) has been performed by magnetron sputtering at 400C. This d ...
It is believed that low frequency microinstabilities such as ion temperature gradient (ITG) driven modes and trapped electron modes (TEMs) are largely responsible for the experimentally observed anomalous transport via the ion and electron channels in a to ...