On-column conductivity detection in capillary-chip electrophoresis
Graph Chatbot
Chattez avec Graph Search
Posez n’importe quelle question sur les cours, conférences, exercices, recherches, actualités, etc. de l’EPFL ou essayez les exemples de questions ci-dessous.
AVERTISSEMENT : Le chatbot Graph n'est pas programmé pour fournir des réponses explicites ou catégoriques à vos questions. Il transforme plutôt vos questions en demandes API qui sont distribuées aux différents services informatiques officiellement administrés par l'EPFL. Son but est uniquement de collecter et de recommander des références pertinentes à des contenus que vous pouvez explorer pour vous aider à répondre à vos questions.
Nicotinic acetylcholine receptors are heteropentameric ion channels that open upon activation to a single conducting state. The second transmembrane segments of each subunit were identified as channel-forming elements, but their respective contribution in ...
This thesis reports on the integration of continuous-flow cell separation method for lab-on-a-chip applications. Cell separation methods are widely used in biology to prepare samples prior to analysis. There is a need for a highly sensitive separation meth ...
A minidevice for performing gel-free proteome prefractionation via conventional IEF in soluble carrier ampholyte buffers is reported here. It consists of a compact block of poly-oxymethylene in which eight samples and two electrode chambers are machined. E ...
The interface between two immiscible electrolyte solutions (ITIES), or liquid|liquid interface, provides a defect-free junction for fundamental studies of adsorption phenomena, heterogeneous charge transfer reactions, and phase-formation processes. Recent ...
New fluorinated host compounds, namely, 2,4,6-tris(4-bromo-3-fluorophenoxy) -1,3,5-triazine, 2,4,6-tris(4-bromo-3,5-difluorophenoxy)-1,3,5-triazine, and 2,4,6-tris(4-bromo-2,6-difluorophenoxy)-1,3,5-triazine, were synthesized to investigate the effect of f ...
An array of electrodes on which cells could be grown directly was fabricated using silicon anisotropic etching and a thick-photoresist process and employed for the detection of nitric oxide (NO) released from a population of adherently growing human umbili ...
This thesis presents the fabrication and design of an impedance imaging sensor, and its application to monitoring in-vitro skin culture. Three-dimensional tissue cultures are becoming increasingly important in biological and medical research. There is, how ...
Gel electrophoresis can be used to separate nicked circular DNA molecules of equal length but forming different knot types. At low electric fields, complex knots drift faster than simpler knots. However, at high electric field the opposite is the case and ...
Electrostatically driven MEMS devices commonly operate with electric fields as high at 108 V/m applied across the dielectric between electrodes. Even with the best mechanical design, the electrical design of these devices has a large impact both on perform ...
Institute of Electrical and Electronics Engineers2004
Electrode effects are known for more than 150 years. These effects, with undesirable consequences in industrial aluminium electrolysis, can be used to micro-machine glass with Spark Assisted Chemical Engraving (SACE). In this paper, a novel approach for th ...