Stable isotope ratioThe term stable isotope has a meaning similar to stable nuclide, but is preferably used when speaking of nuclides of a specific element. Hence, the plural form stable isotopes usually refers to isotopes of the same element. The relative abundance of such stable isotopes can be measured experimentally (isotope analysis), yielding an isotope ratio that can be used as a research tool. Theoretically, such stable isotopes could include the radiogenic daughter products of radioactive decay, used in radiometric dating.
Composition isotopiqueLa composition isotopique d'un échantillon indique les proportions des divers isotopes d'un élément chimique particulier (ou de plusieurs éléments) dans cet échantillon. Les noyaux de tous les atomes d'un même élément chimique comportent le même nombre de protons (ce nombre est aussi celui des électrons présents dans le cortège électronique qui enveloppe le noyau de l'atome neutre) mais peuvent comporter différents nombres de neutrons. Les atomes qui ne diffèrent que par le nombre de neutrons sont des isotopes d'un même élément chimique.
Fractionnement isotopiqueUn fractionnement isotopique est une différence de comportement entre différents isotopes d'un même élément chimique lors d'un processus physique ou chimique donné, si bien que le ou les rapports isotopiques varient au cours du processus. C'est notamment le cas lors d'un changement d'état inabouti, d'une réaction chimique partielle ou d'un écoulement à travers un milieu poreux : le produit de la transformation partielle a une composition isotopique légèrement différente de celle du matériau de départ.
Mass-independent fractionationMass-independent isotope fractionation or Non-mass-dependent fractionation (NMD), refers to any chemical or physical process that acts to separate isotopes, where the amount of separation does not scale in proportion with the difference in the masses of the isotopes. Most isotopic fractionations (including typical kinetic fractionations and equilibrium fractionations) are caused by the effects of the mass of an isotope on atomic or molecular velocities, diffusivities or bond strengths.
Géochimie isotopiqueLa géologie isotopique est une branche de la géologie, apparentée à la géochimie, qui exploite l'étude des isotopes stables et radioactifs présents sur Terre pour en étudier la composition et les variations au cours des temps géologiques. À l'origine, la géologie isotopique a consisté à utiliser les connaissances concernant la radioactivité afin de dater des roches et des minéraux. Cette discipline, au carrefour de la géologie et de la physique nucléaire, s'est surtout illustrée par ses méthodes de datation absolue.
Kinetic fractionationKinetic fractionation is an isotopic fractionation process that separates stable isotopes from each other by their mass during unidirectional processes. Biological processes are generally unidirectional and are very good examples of "kinetic" isotope reactions. All organisms preferentially use lighter isotopic species, because "energy costs" are lower, resulting in a significant fractionation between the substrate (heavier) and the biologically mediated product (lighter).
Tandem mass spectrometryTandem mass spectrometry, also known as MS/MS or MS2, is a technique in instrumental analysis where two or more mass analyzers are coupled together using an additional reaction step to increase their abilities to analyse chemical samples. A common use of tandem MS is the analysis of biomolecules, such as proteins and peptides. The molecules of a given sample are ionized and the first spectrometer (designated MS1) separates these ions by their mass-to-charge ratio (often given as m/z or m/Q).
Proton-transfer-reaction mass spectrometryProton-transfer-reaction mass spectrometry (PTR-MS) is an analytical chemistry technique that uses gas phase hydronium reagent ions which are produced in an ion source. PTR-MS is used for online monitoring of volatile organic compounds (VOCs) in ambient air and was developed in 1995 by scientists at the Institut für Ionenphysik at the Leopold-Franzens University in Innsbruck, Austria. A PTR-MS instrument consists of an ion source that is directly connected to a drift tube (in contrast to SIFT-MS no mass filter is interconnected) and an analyzing system (quadrupole mass analyzer or time-of-flight mass spectrometer).
Transfert thermiquevignette|alt=Autour d'un feu, des mains reçoivent sa chaleur par rayonnement (sur le côté), par convection (au-dessus de ses flammes) et par conduction (à travers un ustensile en métal).|Les modes de transfert thermique ( en anglais pour « rayonnement »). Un transfert thermique, appelé plus communément chaleur, est l'un des modes d'échange d'énergie interne entre deux systèmes, l'autre étant le travail : c'est un transfert d'énergie thermique qui s'effectue hors de l'équilibre thermodynamique.
Transition de phasevignette|droite|Noms exclusifs des transitions de phase en thermodynamique. En physique, une transition de phase est la transformation physique d'un système d'une phase vers une autre, induite par la variation d'un paramètre de contrôle externe (température, champ magnétique...). Une telle transition se produit lorsque ce paramètre externe atteint une valeur seuil (ou valeur « critique »). La transformation traduit généralement un changement des propriétés de symétrie du système.