Publication

Thermal-Aware Design of of 3D ICs with Inter-Tier Liquid Cooling

David Atienza Alonso
2010
Article de conférence
Résumé

Advances in manufacturing technologies are enabling the development of 3D multi-processor ICs, but heat in 3D stacking can lead to degraded performance due to higher power density, which derives from the placement of computational units and storage components on top of each other. Since it is more difficult to remove the heat from 3D ICs, cooling can become the main limiting factor for future 3D multiprocessor system-on-chip (MPSoCs). This paper presents a novel thermal-aware design paradigm for 3D ICs, which includes thermal modeling as a fundamental step to design 3D with inter-tier liquid cooling as well as system-level dynamic thermal management to tune the coolant flow rate to achieve energy-efficient thermally-balanced 3D MPSoCs

À propos de ce résultat
Cette page est générée automatiquement et peut contenir des informations qui ne sont pas correctes, complètes, à jour ou pertinentes par rapport à votre recherche. Il en va de même pour toutes les autres pages de ce site. Veillez à vérifier les informations auprès des sources officielles de l'EPFL.

Graph Chatbot

Chattez avec Graph Search

Posez n’importe quelle question sur les cours, conférences, exercices, recherches, actualités, etc. de l’EPFL ou essayez les exemples de questions ci-dessous.

AVERTISSEMENT : Le chatbot Graph n'est pas programmé pour fournir des réponses explicites ou catégoriques à vos questions. Il transforme plutôt vos questions en demandes API qui sont distribuées aux différents services informatiques officiellement administrés par l'EPFL. Son but est uniquement de collecter et de recommander des références pertinentes à des contenus que vous pouvez explorer pour vous aider à répondre à vos questions.