Infrared vibrational predissociation spectroscopy of van der Waals clusters
Graph Chatbot
Chattez avec Graph Search
Posez n’importe quelle question sur les cours, conférences, exercices, recherches, actualités, etc. de l’EPFL ou essayez les exemples de questions ci-dessous.
AVERTISSEMENT : Le chatbot Graph n'est pas programmé pour fournir des réponses explicites ou catégoriques à vos questions. Il transforme plutôt vos questions en demandes API qui sont distribuées aux différents services informatiques officiellement administrés par l'EPFL. Son but est uniquement de collecter et de recommander des références pertinentes à des contenus que vous pouvez explorer pour vous aider à répondre à vos questions.
We describe a new spectrometer for spin resolved photoemission from solids in the soft x-ray energy range. It is mounted on the ID08 beamline at the ESRF light source and consists of a time-of-flight (TOF) energy analyzer coupled to a retarding mini-Mott s ...
A high-fluence proton irradiation of neptunium was the last experiment in PSIs programme ATHENA related to accelerator-based transmutation. The principal aim of the programme has been to provide experimental data for the validation of theoretical models in ...
An on-plate specific enrichment method is presented for the direct analysis of peptides phosphorylation. An array of sintered TiO2 nanoparticle spots was prepared on a stainless steel plate to provide porous substrate with a very large specific surface and ...
We present in this work a new technique, which combines laser photofragmentation spectroscopy with tandem mass spectrometry, for structural investigations of biomolecular ions in the gas phase. A novel apparatus was designed and built for the implementatio ...
Electron Beam Induced Deposition (EBID) allows deposition of three-dimensional micro- and nano-structures of conductive and insulating materials on a wide range of substrates. The process is based on the decomposition of molecules of a pre-selected precurs ...
A new algorithm is suggested for estn. of peak positions in FTMS spectra. Theor. and exptl. the new technique yields superior results compared to the currently applied techniques, when the noise level is high and/or the peaks are located close to each othe ...
Attachment-induced ionization instability has been experimentally observed in O-2 and CF4 capacitive RF discharges using time-resolved voltage probe, Langmuir probe, optical emission and mass spectrometry measurements. This instability occurs under specifi ...
It is well known in secondary ion mass spectrometry (SIMS) that sample topography leads to decreased mass resolution. Specifically, the ion's time of flight is dependent on where it was generated. Here, using matrix-enhanced SIMS, it is demonstrated that, ...
Recent advances in peptide fragmentation techniques and mass spectrometry have opened up the possibility of combining peptide sepn. techniques, such as capillary electrophoresis (CE) and capillary liq. chromatog., with Fourier transform ion cyclotron reson ...
This study explores the potential of MALDI-TOF MS for the mass measurement of large non-covalent protein complexes. The following non-covalent complexes have been investigated: aerolysin from Aeromonas hydrophila (335 kDa) and α-haemolysin from Staphylococ ...