Automated Analysis of Rare Biomarkers Using a Magnetic Bead Surface Coverage Assay Coupled with Chaotic Mixing on a Microfluidic Chip
Graph Chatbot
Chattez avec Graph Search
Posez n’importe quelle question sur les cours, conférences, exercices, recherches, actualités, etc. de l’EPFL ou essayez les exemples de questions ci-dessous.
AVERTISSEMENT : Le chatbot Graph n'est pas programmé pour fournir des réponses explicites ou catégoriques à vos questions. Il transforme plutôt vos questions en demandes API qui sont distribuées aux différents services informatiques officiellement administrés par l'EPFL. Son but est uniquement de collecter et de recommander des références pertinentes à des contenus que vous pouvez explorer pour vous aider à répondre à vos questions.
We present a novel nonenzymatic carbon nanotube sensor integrated in a microfluidic channel for the detection of sugars. The sensor is assembled as a liquid-gated field-effect transistor, with the transistor channel composed of 1 to 10 nanotubes, which are ...
Methods to manipulate and visualize isolated DNA and oligonucleotide strands are important for investigation of their biophysics as well as their interactions with proteins. Herein, we report such a method by combining a block copolymer surface functionali ...
Using magnetic micro- and nanoparticles (beads) in microfluidic chips opens new perspectives for miniaturized applications in analytical sciences. Four important application areas of magnetic particles in microfluidic systems are discussed. The first one i ...
We present an optofluidic chip with integrated polymer interferometers for measuring both the microfluidic air pressure and flow rate. The chip contains a microfluidic circuit and optical cavities on a polymer which was defined by soft lithography. The pre ...
We introduce for the first time an integrated optofluidic interferometer on a PDMS microfluidic chip. By imaging the local interference patterns inside the chip, both of the fluid pressure and flow rate can be measured. (C) 2009 Optical Society of America ...
Ieee Service Center, 445 Hoes Lane, Po Box 1331, Piscataway, Nj 08855-1331 Usa2010
Abstract Microfluidics for most bio-related diagnostic applications typically requires single usage disposable chips to avoid bio-fouling and cross-contamination. Individual piece-wise manufacturing of polymeric microfluidic devices has been widely employe ...
Separation and subsequent culturing of MCF-7 breast cancer cells on self-assembled protein-coated magnetic beads in a microfluidic chip is demonstrated. The beads were patterned in situ inside a sealed microfluidic channel using magnetic-field-assisted ele ...
We performed a direct immunoassay inside a microfluidic channel on patterned streptavidin-coated beads, which captured fluorescently-labeled biotin target molecules from a continuous flow. We arranged the beads in a dot array at the bottom of the channel a ...
Performances of surface biosensors are often controlled by the analyte delivery rate to the sensing surface instead of sensors intrinsic detection capabilities. In a microfluidic channel, analyte transports diffusively to the biosensor surface severely lim ...
Performances of the biosensors are often limited by the depletion zones created around the sensing area which impede the effective analyte transport. To overcome this limitation, we propose and demonstrate a nanoplasmonic-nanofluidic sensor enabling target ...