Phase-contrast X-ray imagingPhase-contrast X-ray imaging or phase-sensitive X-ray imaging is a general term for different technical methods that use information concerning changes in the phase of an X-ray beam that passes through an object in order to create its images. Standard X-ray imaging techniques like radiography or computed tomography (CT) rely on a decrease of the X-ray beam's intensity (attenuation) when traversing the sample, which can be measured directly with the assistance of an X-ray detector.
Iterative reconstructionIterative reconstruction refers to iterative algorithms used to reconstruct 2D and 3D images in certain imaging techniques. For example, in computed tomography an image must be reconstructed from projections of an object. Here, iterative reconstruction techniques are usually a better, but computationally more expensive alternative to the common filtered back projection (FBP) method, which directly calculates the image in a single reconstruction step.
Tomographic reconstructionTomographic reconstruction is a type of multidimensional inverse problem where the challenge is to yield an estimate of a specific system from a finite number of projections. The mathematical basis for tomographic imaging was laid down by Johann Radon. A notable example of applications is the reconstruction of computed tomography (CT) where cross-sectional images of patients are obtained in non-invasive manner.
Radiographievignette|droite|redresse=1.2|Radiographie pulmonaire numérisée. La radiographie est une technique d', par rayons X dans le cadre de la radiographie X, ou par rayons gamma en gammagraphie. Les rayons X sont des ondes électromagnétiques de hautes fréquences de l'ordre de 1016 Hz à 1020 Hz et qui pénètrent la matière condensée (solides et liquides). Elle permet d'obtenir un cliché dont le contraste dépend à la fois de l'épaisseur et du coefficient d'atténuation des structures traversées.
Générateur de rayons XUn générateur de rayons X est un appareil qui est utilisé pour produire des rayons X. Ces appareils sont utilisés dans les domaines de la radiologie humaine, dentaire et industrielle et possèdent des spécifications très variables en fonction de leur application. Un générateur de rayons X est constitué d'un générateur haute tension (entre et plusieurs MV dans les accélérateurs linéaires) qui alimente un tube à rayons X.
Rayon Xvignette|upright|Une des premières radiographies, prise par Wilhelm Röntgen. alt=Rayon X des poumons humains|vignette|189x189px|Rayon X des poumons humains. Les rayons X sont une forme de rayonnement électromagnétique à haute fréquence constitué de photons dont l'énergie varie d'une centaine d'eV (électron-volt), à plusieurs MeV. Ce rayonnement a été découvert en 1895 par le physicien allemand Wilhelm Röntgen, qui a reçu pour cela le premier prix Nobel de physique ; il lui donna le nom habituel de l'inconnue en mathématiques, X.
X-ray image intensifierAn X-ray image intensifier (XRII) is an that converts X-rays into visible light at higher intensity than the more traditional fluorescent screens can. Such intensifiers are used in X-ray imaging systems (such as fluoroscopes) to allow low-intensity X-rays to be converted to a conveniently bright visible light output. The device contains a low absorbency/scatter input window, typically aluminum, input fluorescent screen, photocathode, electron optics, output fluorescent screen and output window.
Microscope à contraste de phasethumb|Photographie d'un cellule épithéliale de joue vue par un Microscope à contraste de phase Le microscope à contraste de phase est un microscope qui exploite les changements de phase d'une onde lumineuse traversant un échantillon. Cet instrument fut développé par le physicien hollandais Frederik Zernike dans les années 1930, ce qui lui valut le prix Nobel de physique en 1953. Emilie Bleeker, physicienne reconnue pour le développement d'instruments, est la première à mettre le microscope à contraste de phase en utilisation.
Phase-contrast imagingPhase-contrast imaging is a method of that has a range of different applications. It measures differences in the refractive index of different materials to differentiate between structures under analysis. In conventional light microscopy, phase contrast can be employed to distinguish between structures of similar transparency, and to examine crystals on the basis of their double refraction. This has uses in biological, medical and geological science.
Tube à rayons XLes tubes à rayons X sont des dispositifs permettant de produire des rayons X, en général pour trois types d'applications : radiographie et tomographie (, science des matériaux) ; Cristallographie aux rayons X (diffraction de rayons X, voir aussi l'article Diffractomètre) ; analyse chimique élémentaire par spectrométrie de fluorescence des rayons X. Il existe plusieurs types de tubes. Quel que soit le type de tube, la génération des rayons X se fait selon le même principe.