Phase-contrast X-ray imagingPhase-contrast X-ray imaging or phase-sensitive X-ray imaging is a general term for different technical methods that use information concerning changes in the phase of an X-ray beam that passes through an object in order to create its images. Standard X-ray imaging techniques like radiography or computed tomography (CT) rely on a decrease of the X-ray beam's intensity (attenuation) when traversing the sample, which can be measured directly with the assistance of an X-ray detector.
Phase-contrast imagingPhase-contrast imaging is a method of that has a range of different applications. It measures differences in the refractive index of different materials to differentiate between structures under analysis. In conventional light microscopy, phase contrast can be employed to distinguish between structures of similar transparency, and to examine crystals on the basis of their double refraction. This has uses in biological, medical and geological science.
Microscope à contraste de phasethumb|Photographie d'un cellule épithéliale de joue vue par un Microscope à contraste de phase Le microscope à contraste de phase est un microscope qui exploite les changements de phase d'une onde lumineuse traversant un échantillon. Cet instrument fut développé par le physicien hollandais Frederik Zernike dans les années 1930, ce qui lui valut le prix Nobel de physique en 1953. Emilie Bleeker, physicienne reconnue pour le développement d'instruments, est la première à mettre le microscope à contraste de phase en utilisation.
Réseau de diffractionUn réseau de diffraction est un dispositif optique composé d'une série de fentes parallèles (réseau en transmission), ou de rayures réfléchissantes (réseau en réflexion). Ces traits sont espacés de manière régulière, et l'espacement est appelé le « pas » du réseau. Si la distance entre plusieurs traits est de l'ordre de grandeur de la longueur de cohérence spatiale de la lumière incidente, le réseau permet d'obtenir des figures de diffraction particulières influencées par la répétition.
Tube à rayons XLes tubes à rayons X sont des dispositifs permettant de produire des rayons X, en général pour trois types d'applications : radiographie et tomographie (, science des matériaux) ; Cristallographie aux rayons X (diffraction de rayons X, voir aussi l'article Diffractomètre) ; analyse chimique élémentaire par spectrométrie de fluorescence des rayons X. Il existe plusieurs types de tubes. Quel que soit le type de tube, la génération des rayons X se fait selon le même principe.
Gradientvignette|Chaque champ scalaire est représenté par un dégradé (blanc = valeur basse, noir = valeur haute). Chaque gradient est un champ vectoriel, représenté par des flèches bleues ; chacune pointe dans la direction où le champ scalaire croît le plus vite. vignette|La fonction à deux variables f(x, y) = xe−(x2 + y2) correspond à la température (bleu = valeur basse = froid, rouge = valeur haute = chaud). Le gradient de f est un champ vectoriel, représenté par les flèches bleues ; chacune pointe dans la direction où la température croît le plus vite.
Projectional radiographyProjectional radiography, also known as conventional radiography, is a form of radiography and medical imaging that produces two-dimensional images by X-ray radiation. The image acquisition is generally performed by radiographers, and the images are often examined by radiologists. Both the procedure and any resultant images are often simply called 'X-ray'. Plain radiography or roentgenography generally refers to projectional radiography (without the use of more advanced techniques such as computed tomography that can generate 3D-images).
Spectrométrie de fluorescence des rayons Xthumb|Analyseur portatif (Olympus Delta Professional XRF donnant la quantité de contaminants métalliques ou métalloïdes dans le sol. contaminants préoccupants recherchés sont ici le plomb, le mercure, le cadmium et l'arsenic. La spectrométrie de fluorescence des rayons X (SFX ou FX, ou en anglais XRF pour X-ray fluorescence) est une technique d'analyse chimique utilisant une propriété physique de la matière, la fluorescence de rayons X.
Quantitative phase-contrast microscopyFORCETOC Quantitative phase contrast microscopy or quantitative phase imaging are the collective names for a group of microscopy methods that quantify the phase shift that occurs when light waves pass through a more optically dense object. Translucent objects, like a living human cell, absorb and scatter small amounts of light. This makes translucent objects much easier to observe in ordinary light microscopes. Such objects do, however, induce a phase shift that can be observed using a phase contrast microscope.
Interférométrievignette|Le trajet de la lumière à travers un interféromètre de Michelson. Les deux rayons lumineux avec une source commune se combinent au miroir semi-argenté pour atteindre le détecteur. Ils peuvent interférer de manière constructive (renforcement de l'intensité) si leurs ondes lumineuses arrivent en phase, ou interférer de manière destructive (affaiblissement de l'intensité) s'ils arrivent en déphasage, en fonction des distances exactes entre les trois miroirs.