Numerical model of the ankle joint for the study of total ankle replacement
Graph Chatbot
Chattez avec Graph Search
Posez n’importe quelle question sur les cours, conférences, exercices, recherches, actualités, etc. de l’EPFL ou essayez les exemples de questions ci-dessous.
AVERTISSEMENT : Le chatbot Graph n'est pas programmé pour fournir des réponses explicites ou catégoriques à vos questions. Il transforme plutôt vos questions en demandes API qui sont distribuées aux différents services informatiques officiellement administrés par l'EPFL. Son but est uniquement de collecter et de recommander des références pertinentes à des contenus que vous pouvez explorer pour vous aider à répondre à vos questions.
The invention relates to a surgical device (10), comprising a tubular outer shaft (12,) and an inner element (14) having an elongated shape, the outer shaft comprising a distal (30a) and a proximal (30b) outer hinges, the inner element comprising an inner ...
Knee adduction moment (KAM) is correlated with the progression of medial knee osteoarthritis (OA). Although a generic gait modification can reduce the KAM in some patients, it may have a reverse effect on other patients. We proposed the "decomposed ground ...
BackgroundTotal knee arthroplasty (TKA) is most frequently planned using conventional two-dimensional weight-bearing lower limb radiographs and is performed with conventional femoral and tibial cutting guides. Questions have been raised about the accuracy ...
Although the procedure of total knee replacement (TKR) has been improved for the last decades, patients may still face postoperative complications. Specially, causes of complications related to patellar resurfacing, such as osteonecrosis, patellar bone fra ...
Subject-specific modelling of Total Knee Arthroplasty could be an efficient method to preoperatively evaluate surgical options. In particular, the question of the necessity of patellar resurfacing is still a debatable issue. The aim of this work was to val ...
Functional calibration methods were devised to improve repeatability and accuracy of the knee flexion-extension axis, which is used to define the medio-lateral axis of the femur coordinate system in gait analysis. Repeatability of functional calibration me ...
Osteoarthritis is a degenerative disease characterized by damage of the cartilage. A solution to this problem is total knee arthroplasty (TKA). However, there is still complication after total knee arthroplasty with patella resurfacing. In fact, most patel ...
Accurate measurement of knee kinematics during functional activities suffers mainly from soft tissue artifact (STA): the combination of local surface deformations and rigid movement of markers relative to the underlying bone (also called rigid STA movement ...
Functional Hallux Limitus (FHL) is a relatively unknown clinical entity in which dorsal flexion of the first metatarsophalangeal joint is restricted during final stance phase, derailing the three mechanisms of foot stabilization 1. The close packing of the ...
2014
In the framework of the development of new nuclear plants, we have studied the feasibility of producing cladding tubes in new grades adapted to the severe mechanical, thermal and irradiation conditions. ODS steel grades have been identified as promising ma ...