Lateral force resisting mechanisms in slab-column connections: An analytical approach
Publications associées (120)
Graph Chatbot
Chattez avec Graph Search
Posez n’importe quelle question sur les cours, conférences, exercices, recherches, actualités, etc. de l’EPFL ou essayez les exemples de questions ci-dessous.
AVERTISSEMENT : Le chatbot Graph n'est pas programmé pour fournir des réponses explicites ou catégoriques à vos questions. Il transforme plutôt vos questions en demandes API qui sont distribuées aux différents services informatiques officiellement administrés par l'EPFL. Son but est uniquement de collecter et de recommander des références pertinentes à des contenus que vous pouvez explorer pour vous aider à répondre à vos questions.
Reinforced concrete flat slabs constitute one of the most common and efficient modern construction methods. The design of such structural system might be governed by a brittle failure in the vicinity of the slab-column connection associated to punching she ...
Recent earthquakes in Chile (2010, M 8.8) and New Zealand (2011, M 6.3) have shown that, despite many years of extensive research and subsequent design code advancements, several modern reinforced concrete walls underperformed or even failed during these s ...
In many countries of moderate to high seismicity, reinforced concrete (RC) core walls are used as lateral bracing systems in mid- to high-rise buildings where they typically accommodate lift shafts or stair cases. Unlike planar walls which provide horizont ...
Steel concentrically braced frames inherently provide great strength and stiffness, and are widely used for seismic resisting systems in buildings. These include conventional buckling braced frames and buckling restrained braced frames. Although the latter ...
Reinforced concrete (RC) flat slabs supported by slender columns are often used as gravity load resisting system for buildings in regions of moderate and high seismicity. Such buildings are typically braced by RC walls, which carry the largest portion of t ...
Damage to structural walls in the recent earthquakes in Chile (2010) and New Zealand (2011) demonstrated that modern reinforced concrete (RC) walls may not achieve the expected ductile response but could possibly be triggered by out-of-plane displacements ...
An analytical model describing the flexural response of vertically spanning out-of-plane loaded unreinforced masonry walls is presented in this paper. The model is based on the second-order Euler-Bernoulli beam theory and captures important characteristics ...
Provisions for punching shear design of reinforced concrete slabs are usually calibrated on the basis of results from tests on isolated specimens that simulate the slab zone within the points of contraflexure around a column. However, the punching behavior ...
The Multi-Directional Hybrid Testing System (MDHTS) at Polytechnique Montreal is an advanced structural testing system that can be used to study the response of large-scale structural components such as columns, walls, or bridge piers subjected to any comb ...
Reinforced concrete (RC) framed structures subjected to seismic loading often show localized deformations at the extremities of the members associated with the slippage of reinforcing bars along their anchorage length. Despite this phenomenon being respons ...