Adiabatic Demagnetisation Refrigeration Extension for SQUID Magnetometer
Publications associées (32)
Graph Chatbot
Chattez avec Graph Search
Posez n’importe quelle question sur les cours, conférences, exercices, recherches, actualités, etc. de l’EPFL ou essayez les exemples de questions ci-dessous.
AVERTISSEMENT : Le chatbot Graph n'est pas programmé pour fournir des réponses explicites ou catégoriques à vos questions. Il transforme plutôt vos questions en demandes API qui sont distribuées aux différents services informatiques officiellement administrés par l'EPFL. Son but est uniquement de collecter et de recommander des références pertinentes à des contenus que vous pouvez explorer pour vous aider à répondre à vos questions.
Thermal designers of data centers and server manufacturers are showing a greater concern regarding the cooling of the new generation data centers, which consume considerably more electricity and dissipate much more waste heat, a situation that is creating ...
The analysis of cooling of a binary HTS 20 kA current lead (CL) operating between 4.5 and 300 K has been carried out. Assuming that the HTS module is conduction-cooled, two cooling options for the copper heat exchanger (HEX) part of the CL have been consid ...
Cooling of datacenters is estimated to have an annual electricity cost of 1.4 billion dollars in the United States and 3.6 billion dollars worldwide. Currently, refrigerated air is the most widely used means of cooling datacenter’s servers. Modern datacent ...
Thermally sprayed hardmetal coatings can be used to improve the wear or fatigue resistance of mechanical parts. Depending on the deposition conditions, their microstructure and phase composition are out of equilibrium at different levels due to the extreme ...
Trans Tech Publications Ltd, Laublsrutistr 24, Ch-8717 Stafa-Zurich, Switzerland2012
Thermal designers of data centers and server manufacturers are showing a great concern regarding the cooling of new generation data centers, which are more compact and dissipate more power than is currently possible to cool by conventional air conditioning ...
Thermal designers of data centers and server manufacturers are showing a greater concern regarding the cooling of the new generation data centers, which consume considerably more electricity and dissipate much more waste heat, a situation that is creating ...
We describe a low-temperature thermodynamic model for dynamic nuclear polarization (DNP) via continuous-wave partial saturation of electron spin resonance (ESR) lines that are both homogeneously and inhomogeneously broadened. It is a variant of a reasoning ...
The analysis of cooling of a binary HTS 20 kA current lead (CL) operating between 4.5 and 300 K has been carried out. Assuming that the HTS module is conduction-cooled, two cooling options for the copper heat exchanger (HEX) part of the CL have been consid ...
The irradiation hardening of the Eurofer97 steel following 590 MeV proton irradiations was determined at three different irradiation temperatures, 50 °C, 250 °C and 350 °C, and various doses up to about 1.3 displacement per atom. The dose and temperature d ...
The thermally induced hysteretic spin transition (ST) that occurs in the polymeric chain compound Fe(NH(2)trz)(3)(2) (1) above room temperature (T-c(sic) = 347 K, T-c(sic) = 314 K) has been tracked by Fe-57 Mossbauer spectroscopy, SQUID magnetometry ...