Residual-current deviceA residual-current device (RCD), residual-current circuit breaker (RCCB) or ground fault circuit interrupter (GFCI) is an electrical safety device that quickly breaks an electrical circuit with leakage current to ground. It is to protect equipment and to reduce the risk of serious harm from an ongoing electric shock. Injury may still occur in some cases, for example if a human receives a brief shock before the electrical circuit is isolated, falls after receiving a shock, or if the person touches both conductors at the same time.
Electrical faultIn an electric power system, a fault or fault current is any abnormal electric current. For example, a short circuit is a fault in which a live wire touches a neutral or ground wire. An open-circuit fault occurs if a circuit is interrupted by a failure of a current-carrying wire (phase or neutral) or a blown fuse or circuit breaker. In three-phase systems, a fault may involve one or more phases and ground, or may occur only between phases. In a "ground fault" or "earth fault", current flows into the earth.
Split-phase electric powerA split-phase or single-phase three-wire system is a type of single-phase electric power distribution. It is the alternating current (AC) equivalent of the original Edison Machine Works three-wire direct-current system. Its primary advantage is that, for a given capacity of a distribution system, it saves conductor material over a single-ended single-phase system, while only requiring a single phase on the supply side of the distribution transformer. This system is common in North America for residential and light commercial applications.
Single-wire earth returnSingle-wire earth return (SWER) or single-wire ground return is a single-wire transmission line which supplies single-phase electric power from an electrical grid to remote areas at lowest cost. Its distinguishing feature is that the earth (or sometimes a body of water) is used as the return path for the current, to avoid the need for a second wire (or neutral wire) to act as a return path. Single-wire earth return is principally used for rural electrification, but also finds use for larger isolated loads such as water pumps.
Ground and neutralIn electrical engineering, ground and neutral are circuit conductors used in alternating current (AC) electrical systems. The ground circuit is connected to earth, and neutral circuit is usually connected to ground. As the neutral point of an electrical supply system is often connected to earth ground, ground and neutral are closely related. Under certain conditions, a conductor used to connect to a system neutral is also used for grounding (earthing) of equipment and structures.
Earth-leakage circuit breakerAn earth-leakage circuit breaker (ELCB) is a safety device used in electrical installations with high Earth impedance to prevent shock. It detects small stray voltages on the metal enclosures of electrical equipment, and interrupts the circuit if a dangerous voltage is detected. Once widely used, more recent installations instead use residual-current devices (RCDs, RCCBs or GFCIs) which instead detect leakage current directly. The main purpose of Earth leakage protectors is to prevent injury to humans and animals due to electric shock.
Disjoncteurthumb|upright=1.2|Un disjoncteur bipolaire monté sur rail. Les deux contacteurs solidaires sont en parallèle, mais il existe aussi des disjoncteurs bipoles en monocontacteur. Un disjoncteur est un interrupteur électrique à commande automatique conçu pour laisser circuler le courant électrique, et, protéger un circuit électrique contre les dommages causés par un courant excessif provenant d'une surcharge, d'un court-circuit ou d'une fuite à la terre (disjoncteur différentiel).
Courant monophaséUn courant monophasé est un courant électrique alternatif fourni au moyen d'une ligne bifilaire. Il s'oppose aux courants polyphasés, tels que le courant triphasé, pour lesquels plusieurs lignes sont utilisées et déphasées entre elles. Le courant monophasé est principalement utilisé pour l'éclairage et le chauffage, lorsque l'emploi de moteurs de forte puissance n'est pas nécessaire. Un courant monophasé peut être produit à partir d'un courant triphasé en connectant une des trois phases et le neutre, ou en connectant deux des trois phases.
Tableau électriquevignette|droite|Tableau électrique. Un tableau électrique est un tableau de répartition comportant différents types d'appareillage associés à un ou plusieurs circuits électriques de départ alimentés par un ou plusieurs circuits électriques d'arrivée, ainsi que des bornes pour les conducteurs neutre et de protection. Ce regroupement, suivant l'importance de l'installation, peut être un simple coffret (appartement, villa), une armoire ou tout un local avec divers armoires et coffrets que l'on appelle généralement tableau général basse tension (TGBT).
Terre (électricité)En électricité, la terre est un concept qui représente le sol (la masse terreuse, d'où son nom) en le considérant comme parfaitement conducteur et, par convention, au potentiel . Cette dernière hypothèse peut être invalidée si le sol est peu conducteur, par exemple dans le cas du sable dans le désert ou du granit peu fissuré. La définition juridique française est : Cette définition repose sur l'hypothèse que la terre est parfaitement conductrice et que son potentiel est le même en tout point.