Phase-contrast X-ray imagingPhase-contrast X-ray imaging or phase-sensitive X-ray imaging is a general term for different technical methods that use information concerning changes in the phase of an X-ray beam that passes through an object in order to create its images. Standard X-ray imaging techniques like radiography or computed tomography (CT) rely on a decrease of the X-ray beam's intensity (attenuation) when traversing the sample, which can be measured directly with the assistance of an X-ray detector.
Tomographic reconstructionTomographic reconstruction is a type of multidimensional inverse problem where the challenge is to yield an estimate of a specific system from a finite number of projections. The mathematical basis for tomographic imaging was laid down by Johann Radon. A notable example of applications is the reconstruction of computed tomography (CT) where cross-sectional images of patients are obtained in non-invasive manner.
Phase-contrast imagingPhase-contrast imaging is a method of that has a range of different applications. It measures differences in the refractive index of different materials to differentiate between structures under analysis. In conventional light microscopy, phase contrast can be employed to distinguish between structures of similar transparency, and to examine crystals on the basis of their double refraction. This has uses in biological, medical and geological science.
Tomographie par émission de positonsvignette|Reconstruction tridimensionnelle de la distribution de glucose marqué au telle que mesurée par tomographie d'émission de positons. Outre l'accumulation normale du traceur dans le cœur, la vessie, les reins et le cerveau, des métastases hépatiques d'une tumeur colorectale sont clairement visibles dans la région abdominale de l'image.
Microscope à contraste de phasethumb|Photographie d'un cellule épithéliale de joue vue par un Microscope à contraste de phase Le microscope à contraste de phase est un microscope qui exploite les changements de phase d'une onde lumineuse traversant un échantillon. Cet instrument fut développé par le physicien hollandais Frederik Zernike dans les années 1930, ce qui lui valut le prix Nobel de physique en 1953. Emilie Bleeker, physicienne reconnue pour le développement d'instruments, est la première à mettre le microscope à contraste de phase en utilisation.
Quantitative phase-contrast microscopyFORCETOC Quantitative phase contrast microscopy or quantitative phase imaging are the collective names for a group of microscopy methods that quantify the phase shift that occurs when light waves pass through a more optically dense object. Translucent objects, like a living human cell, absorb and scatter small amounts of light. This makes translucent objects much easier to observe in ordinary light microscopes. Such objects do, however, induce a phase shift that can be observed using a phase contrast microscope.
Iterative reconstructionIterative reconstruction refers to iterative algorithms used to reconstruct 2D and 3D images in certain imaging techniques. For example, in computed tomography an image must be reconstructed from projections of an object. Here, iterative reconstruction techniques are usually a better, but computationally more expensive alternative to the common filtered back projection (FBP) method, which directly calculates the image in a single reconstruction step.
Tomographievignette|Principe de base de la tomographie par projections : les coupes tomographiques transversales S1 et S2 sont superposées et comparées à l’image projetée P. La tomographie est une technique d’, très utilisée dans l’, ainsi qu’en géophysique, en astrophysique et en mécanique des matériaux. Cette technique permet de reconstruire le volume d’un objet à partir d’une série de mesures effectuées depuis l’extérieur de cet objet.
Tomographie par émission monophotoniquevignette|droite|Image dans le plan axial du cerveau obtenue par tomographie d'émission monophotonique utilisant le Tc-99. La tomographie par émission monophotonique, en abrégé TEMP, ou même SPECT (de l'Single photon emission computed tomography), aussi appelée tomoscintigraphie par émission monophotonique, est une technique qui repose sur le principe de la scintigraphie et qui permet d'effectuer des images ainsi que des reconstructions en trois dimensions d'organes et de leur métabolisme à l'aide d'un ensemble de gamma caméras tournant autour du patient.
Dose absorbéeEn radioprotection, la dose absorbée, ou, plus concisément, la dose, est l'énergie déposée par unité de masse par un rayonnement ionisant. On la rencontre également sous d'autres noms, notamment dose radiative ou dose radioactive en physique nucléaire. Son intérêt premier est de quantifier l'énergie déposée dans un tissu biologique pour prévoir les effets déterministes et effets stochastiques d'une irradiation : planning de soins des cancers en radiothérapie ou curiethérapie, prédiction des risques de maladie en cas d'exposition accidentelle ou volontaire (radiologie), définition de normes de sécurité dans l'industrie nucléaire, etc.