Static and Fatigue Shear Strength of Reinforced Concrete Slabs Under Concentrated Loads Near Linear Supports
Graph Chatbot
Chattez avec Graph Search
Posez n’importe quelle question sur les cours, conférences, exercices, recherches, actualités, etc. de l’EPFL ou essayez les exemples de questions ci-dessous.
AVERTISSEMENT : Le chatbot Graph n'est pas programmé pour fournir des réponses explicites ou catégoriques à vos questions. Il transforme plutôt vos questions en demandes API qui sont distribuées aux différents services informatiques officiellement administrés par l'EPFL. Son but est uniquement de collecter et de recommander des références pertinentes à des contenus que vous pouvez explorer pour vous aider à répondre à vos questions.
The present research represents a theoretical and experimental contribution to the understanding of the structural behaviour of elements made of ultra-high performance fibre-reinforced concrete (UHPFRC). UHPFRC is investigated as an advanced cementitious m ...
Currently, there is no generally-accepted theory giving a physical explanation of the shear strength in one- and two-way slabs. Furthermore, for members without transverse reinforcement, shear strength is estimated in most codes of practice following empir ...
Reinforced concrete bridge deck slabs without shear reinforcement can be subjected to concentrated or distributed loads of important magnitude. Under these loads their structural response is not always ductile. In particular under concentrated loads their ...
A new connection system for a concrete filled steel tube composite column and reinforced concrete beams is proposed. In this connection, the steel tube is interrupted while the reinforced concrete beams are continuous in the joint zone. Multiple lateral ho ...
This paper presents the results of six tests on R/C bridge cantilever slabs without shear reinforcement subjected to concentrated loading. The specimens represent actual deck slabs of box-girder bridges scaled 3/4. They were 10mlong with a clear cantilever ...
Reinforced concrete flat slabs are extensively used in buildings and parking garages. At the ultimate limit state, their design is usually governed by punching shear. In the case where no punching shear reinforcement is provided, failure develops in a brit ...
7th International fib Symposium in Civil Engineering2008
Currently, estimations of the crack width in the deck slab of bridges given by codes of practice are based on either theoretical or empirical approaches considering mainly the monotonic loading behaviour. However, cracking in reinforced tensile members is ...
The presence of post-tensioning tendons in webs decreases the load-carrying capacity of the compression struts that are necessary to transfer shear forces. This effect has been known for a long time, but was initially not included in design codes. In parti ...
A mechanical explanation of the phenomenon of punching shear in slabs without transverse reinforcement is presented on the basis of the opening of a critical shear crack. It leads to the formulation of a new failure criterion for punching shear based on th ...
This paper investigates the load-carrying mechanisms and the strength of thin-webbed, post-tensioned beams failing by crushing of the web. The shear strength in these members is significantly reduced because of the state of cracking in the web and because ...