Posez n’importe quelle question sur les cours, conférences, exercices, recherches, actualités, etc. de l’EPFL ou essayez les exemples de questions ci-dessous.
AVERTISSEMENT : Le chatbot Graph n'est pas programmé pour fournir des réponses explicites ou catégoriques à vos questions. Il transforme plutôt vos questions en demandes API qui sont distribuées aux différents services informatiques officiellement administrés par l'EPFL. Son but est uniquement de collecter et de recommander des références pertinentes à des contenus que vous pouvez explorer pour vous aider à répondre à vos questions.
Reinforced concrete bridge deck slabs without shear reinforcement can be subjected to concentrated or distributed loads of important magnitude. Under these loads their structural response is not always ductile. In particular under concentrated loads their ...
Reinforced concrete flat slabs are extensively used in buildings and parking garages. At the ultimate limit state, their design is usually governed by punching shear. In the case where no punching shear reinforcement is provided, failure develops in a brit ...
7th International fib Symposium in Civil Engineering2008
This article examines the extent to which post-weld treatment by needle peening can improve the fatigue performance of tubular truss bridges. To do this, the various potential crack sites on several variants of a typical bridge are analyzed using a probabi ...
The present research represents a theoretical and experimental contribution to the understanding of the structural behaviour of elements made of ultra-high performance fibre-reinforced concrete (UHPFRC). UHPFRC is investigated as an advanced cementitious m ...
The contributions assembled in the present volume proceed from the lectures of the 2009 ALERT Geomaterials School devoted to the Failure in the multiphase geomaterials. The multiphase behaviour of geomaterials used to be mainly considered from the point of ...
Punching of reinforced concrete and prestressed slabs is usually a critical failure mode for the design and verification of structures such as flat slabs or bridge slabs. Although codes of practice propose several rules for common cases (usually with an em ...
The behavior of seven one-half scale masonry specimens before and after retrofitting using fiber-reinforced polymer (FRP) is investigated. Four walls were built using one-half scale hollow clay masonry units and weak mortar to simulate walls built in centr ...
Combined loading and climatic effects associated with the choice of high modulus bituminous mixtures, in order to prevent the pavements from rutting, have increased the risk of cracking failure in the bituminous layers. It was decided, in 1989, to start a ...
The construction principles of "Timber-Glass-Composite-Girders" demand practical and theoretical research to ensure reliable designs. Toward this objective the mathematical description of load-bearing and the non-rigid bond is the subject of this work, i.e ...
Punching of flat slabs without transverse reinforcement has mostly been investigated in the past for slabs with equal reinforcement ratios in the two directions and loaded under axis-symmetrical conditions. However, in practice, slab bridges as well as man ...