Experimental investigation on flow boiling pressure drop and heat transfer of R1233zd(E) in a multi-microchannel evaporator
Publications associées (98)
Graph Chatbot
Chattez avec Graph Search
Posez n’importe quelle question sur les cours, conférences, exercices, recherches, actualités, etc. de l’EPFL ou essayez les exemples de questions ci-dessous.
AVERTISSEMENT : Le chatbot Graph n'est pas programmé pour fournir des réponses explicites ou catégoriques à vos questions. Il transforme plutôt vos questions en demandes API qui sont distribuées aux différents services informatiques officiellement administrés par l'EPFL. Son but est uniquement de collecter et de recommander des références pertinentes à des contenus que vous pouvez explorer pour vous aider à répondre à vos questions.
The conversion to the new alternative refrigerants caused by the greenhouse and ozone effects is now replacing nuclear reactor analysis and safety as the major driving force in two-phase heat transfer research. Extensive studies are underway on pool boilin ...
Flow pattern data for horizontal intube flow boiling are presented for refrigerants R-134a and R-402 (60/2/38). The flow pattern observations were compared with various criteria for determining whether the entire circumference of a horizontal evaporator tu ...
Lack of precision and inconsistencies in existing correlations, an attempt was successfully made to develop a new and more mechanistically based correlation (Kattan, 1996 [1]) for boiling inside plain tubes. This new general correlation is original in that ...
As part of a comprehensive study on factors affecting flow boiling in horizontal tubes, local boiling heat transfer coefficients were measured for R- 134a evaporating inside the same 12.00 mm bore, plain tube for horizontal flow, vertical upflow and vertic ...
Intube flow boiling experiments for refrigerant R-134a mixed with a lubricating oil are reported. The tests were run at a nominal inlet pressure of 3.4 bar over a wide range of vapor qualities at mass velocities of 100, 200 and 300 kg/m2s (73500, 147000 an ...
Two-phase flow pattern data were obtained with 12.0 mm bore sight glasses for five refrigerants: R-123, R-134a, R-502, R-402A and R-404A. The existing flow pattern maps of Taitel-Dukler and Hashizume poorly represented the data while the VDI map identified ...
A critical review of evaporation in plain, horizontal tubes is presented, focusing primarly on flow boiling correlations. Emphasis is placed on analyzing the integrity of currently accepted ideas and methods, identifying the weaknesses in current design me ...
Intube flow boiling experiments for two new zeotropic refrigerant mixtures and R-502 have been carried out at three saturation temperatures over a wide range of local vapor qualities. The zeotropic mixtures tested were HP80 and HP62. Local flow boiling coe ...