Experimental investigation on flow boiling pressure drop and heat transfer of R1233zd(E) in a multi-microchannel evaporator
Graph Chatbot
Chat with Graph Search
Ask any question about EPFL courses, lectures, exercises, research, news, etc. or try the example questions below.
DISCLAIMER: The Graph Chatbot is not programmed to provide explicit or categorical answers to your questions. Rather, it transforms your questions into API requests that are distributed across the various IT services officially administered by EPFL. Its purpose is solely to collect and recommend relevant references to content that you can explore to help you answer your questions.
Intube flow boiling experiments for refrigerant R-134a mixed with a lubricating oil are reported. The tests were run at a nominal inlet pressure of 3.4 bar over a wide range of vapor qualities at mass velocities of 100, 200 and 300 kg/m2s (73500, 147000 an ...
A critical review of evaporation in plain, horizontal tubes is presented, focusing primarly on flow boiling correlations. Emphasis is placed on analyzing the integrity of currently accepted ideas and methods, identifying the weaknesses in current design me ...
Two-phase flow pattern data were obtained with 12.0 mm bore sight glasses for five refrigerants: R-123, R-134a, R-502, R-402A and R-404A. The existing flow pattern maps of Taitel-Dukler and Hashizume poorly represented the data while the VDI map identified ...
As part of a comprehensive study on factors affecting flow boiling in horizontal tubes, local boiling heat transfer coefficients were measured for R- 134a evaporating inside the same 12.00 mm bore, plain tube for horizontal flow, vertical upflow and vertic ...
Lack of precision and inconsistencies in existing correlations, an attempt was successfully made to develop a new and more mechanistically based correlation (Kattan, 1996 [1]) for boiling inside plain tubes. This new general correlation is original in that ...
The conversion to the new alternative refrigerants caused by the greenhouse and ozone effects is now replacing nuclear reactor analysis and safety as the major driving force in two-phase heat transfer research. Extensive studies are underway on pool boilin ...
Flow pattern data for horizontal intube flow boiling are presented for refrigerants R-134a and R-402 (60/2/38). The flow pattern observations were compared with various criteria for determining whether the entire circumference of a horizontal evaporator tu ...
Intube flow boiling experiments for two new zeotropic refrigerant mixtures and R-502 have been carried out at three saturation temperatures over a wide range of local vapor qualities. The zeotropic mixtures tested were HP80 and HP62. Local flow boiling coe ...