AVERTISSEMENT : Le chatbot Graph n'est pas programmé pour fournir des réponses explicites ou catégoriques à vos questions. Il transforme plutôt vos questions en demandes API qui sont distribuées aux différents services informatiques officiellement administrés par l'EPFL. Son but est uniquement de collecter et de recommander des références pertinentes à des contenus que vous pouvez explorer pour vous aider à répondre à vos questions.
Over the last few decades, the application of glass in building construction has extended from small four-side supported windowpanes to areas traditionally reserved for other materials, such as roofs, floors, staircases and full building envelopes. Glass i ...
Glass fiber-reinforced polymer (GFRP) pultruded decks and sandwich panels currently represent two of the most extensive applications of FRP materials for load-bearing structural components in the bridge and building domains. Based on the state of the art, ...
Since the first applications of structural concrete, the shear behaviour of one-way slabs without transverse reinforcement has been largely investigated. Nevertheless, currently in the scientific community there is no general agreement on the mechanisms of ...
Reinforced concrete flat slabs constitute one of the most common and efficient modern construction methods. The design of such structural system might be governed by a brittle failure in the vicinity of the slab-column connection associated to punching she ...
Reinforced concrete (RC) flat slabs supported by slender columns are often used as gravity load resisting system for buildings in regions of moderate and high seismicity. Such buildings are typically braced by RC walls, which carry the largest portion of t ...
The seismic design provisions and stability requirements for steel columns used at the first storey of MRFs as specified is Canadian steel design standard (CSA S16), U.S. design provisions for steel buildings (AISC 341 and AISC 360), the New Zealand steel ...
Recent earthquakes in Chile (2010, M 8.8) and New Zealand (2011, M 6.3) have shown that, despite many years of extensive research and subsequent design code advancements, several modern reinforced concrete walls underperformed or even failed during these s ...
concrete footings with and without transverse reinforcement. Even though that punching shear failures have already been deeply investigated, there is still scanty experimental information on full-scale reinforced concrete footings failing in punching shear ...
11th fib International PhD Symposium in Civil Engineering2016
The recent re-assessment of the seismic hazard in Europe led for many regions of low to moderate seismicity to an increase in the seismic demand. As a consequence, several modern unreinforced masonry (URM) buildings, constructed with reinforced concrete (R ...
This paper investigates an innovative bonded sleeve connection for joining tubular GFRP and steel members. Experimental results focused on mechanical responses of beam-to-column specimens using bonded sleeve connections and conventional steel angle connect ...