Assessment of nanoparticles’ safety: corrected absorbance-based toxicity test
Publications associées (8)
Graph Chatbot
Chattez avec Graph Search
Posez n’importe quelle question sur les cours, conférences, exercices, recherches, actualités, etc. de l’EPFL ou essayez les exemples de questions ci-dessous.
AVERTISSEMENT : Le chatbot Graph n'est pas programmé pour fournir des réponses explicites ou catégoriques à vos questions. Il transforme plutôt vos questions en demandes API qui sont distribuées aux différents services informatiques officiellement administrés par l'EPFL. Son but est uniquement de collecter et de recommander des références pertinentes à des contenus que vous pouvez explorer pour vous aider à répondre à vos questions.
In this paper, the total ionizing dose (TID) response of a commercial 28-nm high-k CMOS technology at ultrahigh doses is measured and discussed. The degradation of pMOSFETs depends not only on the channel width but also on the channel length. Short-channel ...
Detection and direct power conversion of high energy and high intensity ionizing radiation could be a key element in next generation nuclear reactor safety systems and space-born devices. For example, the Fukushima catastrophe in 2011 could have been large ...
Reduced activation martensitic steel specimens were irradiated by dual-beam from 0.1 to 50 dpa at 250 and 300 degreesC with 10 He appm/dpa. The in-situ microstructure observation shows that the bubbles were present after 1.7 dpa for 250 degreesC irradiatio ...
OBJECTIVE: How variations of treatment time affect the safety and efficacy of Gamma Knife (GK) radiosurgery is a matter of considerable debate. With the relative simplicity of treatment planning for trigeminal neuralgia (TN), this question has been address ...
The mechanical resistance of UV irradiated optical fibers has been investigated by dynamic fatigue tests. The intrinsic Weibull distribution of the pristine and chemically stripped fiber were almost identical. The high germanium doped fiber was homogeneous ...
Segregation of P and Mo to prior austenite grain boundaries in a 2.25Cr1Mo steel subjected to neutron irradiation and ageing is examined using field emission gull scanning transmission electron microscopy (FEGSTEM) with energy dispersive X-ray microanalysi ...
Objective. Microbeam radiation therapy (MRT) is an alternative emerging radiotherapy treatment modality which has demonstrated effective radioresistant tumour control while sparing surrounding healthy tissue in preclinical trials. This apparent selectivity ...
In the quest of the structural materials for the future fusion reactor, it has been shown that ferritic/martensitic (F/M) steels are very promising candidates, with a good radiation resistance in terms of damage accumulation in the microstructure relative ...