Seismic retrofitSeismic retrofitting is the modification of existing structures to make them more resistant to seismic activity, ground motion, or soil failure due to earthquakes. With better understanding of seismic demand on structures and with our recent experiences with large earthquakes near urban centers, the need of seismic retrofitting is well acknowledged. Prior to the introduction of modern seismic codes in the late 1960s for developed countries (US, Japan etc.) and late 1970s for many other parts of the world (Turkey, China etc.
Construction parasismiquethumb| La Tokyo Skytree, la deuxième plus grande tour au monde (derrière le Burj Khalifa) qui, du haut de ses , a parfaitement résisté au séisme de 2011 de magnitude 9, démontrant l'efficacité des constructions parasismiques japonaises. La construction parasismique ou construction antisismique est la réalisation de bâtiments et infrastructures résistant aux séismes. Elle implique l'étude du comportement des bâtiments et structures sujets à un chargement dynamique de type sismique.
Aléa sismiquevignette|Ceinture de feu du Pacifique L'aléa sismique est la probabilité qu'un séisme destructeur de caractéristiques données (exprimées en général par des paramètres tels que l’accélération, la période de récurrence, l’intensité, le spectre de réponse...) se produise dans une région donnée pendant une période donnée. Il ne doit pas être confondu avec le risque sismique qui est la probabilité qu'un séisme engendre des destructions et fasse des victimes. Ce risque est une combinaison de .
Prévision numérique du tempsLa prévision numérique du temps (PNT) est une application de la météorologie et de l'informatique. Elle repose sur le choix d'équations mathématiques offrant une proche approximation du comportement de l'atmosphère réelle. Ces équations sont ensuite résolues, à l'aide d'un ordinateur, pour obtenir une simulation accélérée des états futurs de l'atmosphère. Le logiciel mettant en œuvre cette simulation est appelé un modèle de prévision numérique du temps.
Seismic analysisSeismic analysis is a subset of structural analysis and is the calculation of the response of a building (or nonbuilding) structure to earthquakes. It is part of the process of structural design, earthquake engineering or structural assessment and retrofit (see structural engineering) in regions where earthquakes are prevalent. As seen in the figure, a building has the potential to 'wave' back and forth during an earthquake (or even a severe wind storm). This is called the 'fundamental mode', and is the lowest frequency of building response.
Ground motionGround motion is the movement of the earth's surface from earthquakes or explosions. Ground motion is produced by seismic waves that are generated by sudden slip on a fault or sudden pressure at the explosive source and travel through the earth and along its surface. This can be due to natural events, such as earthquakes and volcanic eruptions, or human activities, such as the detonation of nuclear weapons. There are two main types of seismic waves: body waves and surface waves.
Seismic loadingSeismic loading is one of the basic concepts of earthquake engineering which means application of an earthquake-generated agitation to a structure. It happens at contact surfaces of a structure either with the ground, or with adjacent structures, or with gravity waves from tsunami. Seismic loading depends, primarily, on: Anticipated earthquake's parameters at the site - known as seismic hazard Geotechnical parameters of the site Structure's parameters Characteristics of the anticipated gravity waves from tsunami (if applicable).
Seismic vibration controlIn earthquake engineering, vibration control is a set of technical means aimed to mitigate seismic impacts in building and non-building structures. All seismic vibration control devices may be classified as passive, active or hybrid where: passive control devices have no feedback capability between them, structural elements and the ground; active control devices incorporate real-time recording instrumentation on the ground integrated with earthquake input processing equipment and actuators within the structure; hybrid control devices have combined features of active and passive control systems.
Strong ground motionIn seismology, strong ground motion is the strong earthquake shaking that occurs close to (less than about 50 km from) a causative fault. The strength of the shaking involved in strong ground motion usually overwhelms a seismometer, forcing the use of accelerographs (or strong ground motion accelerometers) for recording. The science of strong ground motion also deals with the variations of fault rupture, both in total displacement, energy released, and rupture velocity.
Seismic intensity scalesSeismic intensity scales categorize the intensity or severity of ground shaking (quaking) at a given location, such as resulting from an earthquake. They are distinguished from seismic magnitude scales, which measure the magnitude or overall strength of an earthquake, which may, or perhaps may not, cause perceptible shaking. Intensity scales are based on the observed effects of the shaking, such as the degree to which people or animals were alarmed, and the extent and severity of damage to different kinds of structures or natural features.