The ACHIP experimental chambers at the Paul Scherrer Institut
Publications associées (36)
Graph Chatbot
Chattez avec Graph Search
Posez n’importe quelle question sur les cours, conférences, exercices, recherches, actualités, etc. de l’EPFL ou essayez les exemples de questions ci-dessous.
AVERTISSEMENT : Le chatbot Graph n'est pas programmé pour fournir des réponses explicites ou catégoriques à vos questions. Il transforme plutôt vos questions en demandes API qui sont distribuées aux différents services informatiques officiellement administrés par l'EPFL. Son but est uniquement de collecter et de recommander des références pertinentes à des contenus que vous pouvez explorer pour vous aider à répondre à vos questions.
To produce short X-ray pulses for SwissFEL(1), it is necessary to compress the electron bunches by a factor of 300, down to sub-fs for the attosecond operational modes. To achieve stable EEL output accurate timing of the initial electron injection at the m ...
The operation of Nb–Ti superconducting magnets in He II relies on superfluidity to overcome the severe thermal barrier represented by the cable electrical insulation. In wrapped cable insulations, like those used for the main magnets of the Large Hadron Co ...
Coated conductors are promising material for the construction of high field magnets, but the slow propagation velocity of the normal zone makes the protection against quenches a critical issue. The quench protection system for a small insert coil under dev ...
This thesis presents new superconducting compact (as opposed to separated-sector ) cyclotron designs for injection in CABOTO, a linac developed by the TERA Foundation delivering C6+/H2+ beams up to 400 MeV/u for ion beam therapy. This association of a vari ...
Magnetic beads (MB) have now proven to be a powerful tool in both research and biomedical applications. They are available in a wide range of sizes (from nm to several µm) and their surface can be modified with molecules having biological specificities and ...
In this thesis, we present development of the first magnetic model of the main Proton Synchrotron magnets. The operation of the machine and conducting research on increasing its performance require a significant amount of the magnetic field data for the op ...
An existing Nb3Sn laboratory magnet generating a magnetic field of 12 T is intended to be upgraded to 16 T by means of the use of a high temperature superconductor (HTS) insert coil. An outline design of the HTS insert coil is presented. In the design, the ...
The scientific community and the medical industries are putting a considerable effort into the design of compact, reliable and cheap accelerators for hadrontherapy. Up to now only circular accelerators are used to deliver beams with energies suitable for t ...
This paper introduces the concept of ring magnets for magnetic beads (MBs) trapping in a capillary. Such magnets enable an easy insertion of a capillary simply like a pearl on a string. With this system, high magnetic forces are obtained thanks to the prox ...
The energy ramp and the betatron squeeze at the CERN Large Hadron Collider (LHC) are particularly critical oper- ational phases that involve the manipulation of beams well above the safe limit for damage of accelerator components. In particular, the squeez ...