Monitoring of the Chillon viaduct after strengthening with UHPFRC
Publications associées (33)
Graph Chatbot
Chattez avec Graph Search
Posez n’importe quelle question sur les cours, conférences, exercices, recherches, actualités, etc. de l’EPFL ou essayez les exemples de questions ci-dessous.
AVERTISSEMENT : Le chatbot Graph n'est pas programmé pour fournir des réponses explicites ou catégoriques à vos questions. Il transforme plutôt vos questions en demandes API qui sont distribuées aux différents services informatiques officiellement administrés par l'EPFL. Son but est uniquement de collecter et de recommander des références pertinentes à des contenus que vous pouvez explorer pour vous aider à répondre à vos questions.
A new type of connection for steel-concrete composite bridges was developed by the Steel Structures Laboratory of Ecole Polytechnique Fédérale de Lausanne. Resistance to longitudinal shear is based on the development of shear stresses in the confined inter ...
Construction methods for steel-concrete structures have developed significantly over the last quarter of a century, and the number of steel-concrete bridges on road and rail networks is continually increasing. However, design methods for bridges have not e ...
The aim of the present thesis is to provide a numerical tool for the mechanical modeling of dynamic failure in concrete. This widely used construction material is characterized by a non-linear failure behavior, which is consequently difficult to describe w ...
RC slabs without shear reinforcement subjected to c oncentrated loads near lin ear supports are typical cases of deck slabs of bridges, transfer slabs or pile caps. Such elements are often designed or as sessed in shear with code provisions calibrated on ...
Proc. of the 10th fib International PhD Symposium in Civil Engineering, Quebec2014
Reinforced concrete flat slabs are extensively used in buildings and parking garages. Their design is governed by deflection at the serviceability limit state and punching shear at the ultimate limit state. When no punching shear reinforcement is provided, ...
At the end of the 1980’s, a series of existing bridges in Switzerland were equipped with a network of hydrostatic leveling devices, with the aim of following their longterm behavior. Some of the bridges were known to exhibit a steady increase in their defo ...
A new connection system for a concrete filled steel tube composite column and reinforced concrete beams is proposed. In this connection, the steel tube is interrupted while the reinforced concrete beams are continuous in the joint zone. Multiple lateral ho ...
Reinforced concrete flat slabs are a common structural system for cast-in-place concrete slabs. Failures in punching shear near the column regions are typically governing at ultimate. In case no punching shear or integrity reinforcement is placed, failures ...
Punching shear of reinforced concrete flat slabs supported on columns is a failure mode in which the slab fractures around the column. This type of failure is sudden and can be catastrophic in nature. Punching shear generally governs the ultimate limit sta ...
The ultimate strength of reinforced concrete slabs is frequently governed by the punching shear capacity, which may be increased with addition of traditional fitments such as reinforcing steel, headed studs or shear heads. In addition to these traditional ...