Ocular Structures Segmentation from Multi-sequences MRI Using 3D Unet with Fully Connected CRFs
Graph Chatbot
Chattez avec Graph Search
Posez n’importe quelle question sur les cours, conférences, exercices, recherches, actualités, etc. de l’EPFL ou essayez les exemples de questions ci-dessous.
AVERTISSEMENT : Le chatbot Graph n'est pas programmé pour fournir des réponses explicites ou catégoriques à vos questions. Il transforme plutôt vos questions en demandes API qui sont distribuées aux différents services informatiques officiellement administrés par l'EPFL. Son but est uniquement de collecter et de recommander des références pertinentes à des contenus que vous pouvez explorer pour vous aider à répondre à vos questions.
Conventional magnetic resonance imaging (MRI) techniques are highly sensitive to detect multiple sclerosis (MS) plaques, enabling a quantitative assessment of inflammatory activity and lesion load. In quantitative analysis of focal lesions, manual or semi-a ...
The inherent distortions in echo-planar imaging that arise due to inhomogeneities in the static magnetic field can lead to difficulties when attempting to obtain structurally accurate diffusion-tensor imaging data. Parallel acceleration techniques can redu ...
Glaucoma is one of the leading causes of blindness in the world. It results in an increase of the aqueous humour (AH) outflow pathway which leads to an increase of the intraocular pressure (IOP). Many treatments exists to reduce and stabilize the IOP such ...
In magnetic resonance imaging (MRI), it is possible to cancel the effects of severe inhomogeneities of the magnetic field even if the field profile is unknown. The new ‘cross-encoded’ method is based on adiabatic frequency-modulated pulses combined with tw ...
We present a high speed full range spectral domain optical coherence tomography system. By inserting a phase modulator into the reference arm and recording of every other spectrum with a 90° phase shift (introduced by the phase modulator) we are able to di ...
During the last two decades, magnetic resonance imaging (MRI) has evolved into one of the most powerful techniques in medical diagnosis. Among the various medical diagnostic modalities, such as X-ray or ultra-sound imaging, MRI is the technique of choice e ...
A multiple-frequency (9.4-325 GHz) and variable-temperature (276-320 K) electron paramagnetic resonance (EPR) study on low molecular weight gadolinium(III) complexes for potential use as magnetic resonance imaging (MRI) contrast agents has been performed. ...
Functional magnetic resonance imaging (fMRI) measures activation-induced signal changes by means of the blood-oxygenation-level-depended (BOLD) contrast. Since signal changes are typically only 1-3%, the method is intrinsically sensitive to all signal inst ...
Scanning probe microscopy has become, nowadays, a branch of microscopy widely used to image surfaces of different specimens. Among the various applications, the magnetic imaging is one of the most exciting scanning probe microscopy techniques. It allows th ...
Relatively recent developments in medical imaging allow the anatomical and functional noninvasive study of internal organs of the body. One of the most complex and interesting organs in our body is the brain. Many efforts are being carried out to try to un ...