AVERTISSEMENT : Le chatbot Graph n'est pas programmé pour fournir des réponses explicites ou catégoriques à vos questions. Il transforme plutôt vos questions en demandes API qui sont distribuées aux différents services informatiques officiellement administrés par l'EPFL. Son but est uniquement de collecter et de recommander des références pertinentes à des contenus que vous pouvez explorer pour vous aider à répondre à vos questions.
This paper describes the design and the performance of a new high-speed laser Doppler imaging system for monitoring blood flow over an area of tissue. The new imager delivers high-resolution flow images (256 x 256 pixels) every 2 to 10 seconds, depending o ...
Laser Doppler Imaging (LDI) is a non-invasive optical technique used for assessing the blood flow in biological tissue. This technique allows visualizing 2D distribution of blood flow over an extended area of tissue, e.g. human skin. We have developed a ne ...
We propose a method for high dynamic range (HDR) mapping that is directly applied on the color filter array (CFA) image instead of the already demosaiced image. This rendering is closer to retinal processing where an image is acquired by a mosaic of cones ...
The design and characterization of an imaging system is presented for depth information capture of arbitrary three-dimensional (3-D) objects. The core of the system is an array of 32 × 32 rangefinding pixels that independently measure the time-of-flight of ...
We present a virtual digital camera sensor, whose aim is to simulate a real (physical) image capturing sensor.To accomplish this task, the virtual sensor operates in two steps. First, it accepts a physical description of agiven scene and simulates the enti ...
We describe the design and performance of a new full-field high-speed laser Doppler imaging system developed for mapping and monitoring of blood flow in biological tissue. The total imaging time for 256x256 pixels region of interest is 1.2 seconds. An inte ...
In this paper we report on a 32×32 optical imager based on single photon avalanche diodes integrated in CMOS technology. The maximum measured dynamic range is 120dB and the minimum noise equivalent intensity is 1.3×-3lx. The minimum integration time per pi ...
In a previous study, we proposed an adaptive sigma delta modulator with improved dynamic range. The modulator adapts the step size of the quantizer from estimates of the quantizer input instead of the modulator input. In this study, we conduct an error var ...
This work develops an adaptive sigma-delta modulator that is based on adapting the quantizer step-size using estimates of the quantizer input rather than the modulator input. The adaptive modulator with a first-order noise shaping filter is shown to be bou ...
The inventive method for measuring the optical properties of transparent and/or diffusive objects (18), especially their reflection profile, uses two coupled interferometers. Said coupled interferometers are operated with two beams of different coherence l ...