Uncertainties in the Seismic Assessment of Historical Masonry Buildings
Publications associées (39)
Graph Chatbot
Chattez avec Graph Search
Posez n’importe quelle question sur les cours, conférences, exercices, recherches, actualités, etc. de l’EPFL ou essayez les exemples de questions ci-dessous.
AVERTISSEMENT : Le chatbot Graph n'est pas programmé pour fournir des réponses explicites ou catégoriques à vos questions. Il transforme plutôt vos questions en demandes API qui sont distribuées aux différents services informatiques officiellement administrés par l'EPFL. Son but est uniquement de collecter et de recommander des références pertinentes à des contenus que vous pouvez explorer pour vous aider à répondre à vos questions.
The non-linear seismic displacement demand prediction for low-period structures, i.e. with an initial fundamental period situated in the plateau of design response spectra is studied. In Eurocode 8, the computation of seismic displacement demands is essent ...
The seismic assessment of masonry buildings, both modern unreinforced masonry (URM) buildings and historical heritage constructions, is a complex task, characterised by a several sources of uncertainty, which regard the appropriate modelling of strategy th ...
This paper presents a critical review of the state of the art of experimental research concerning the seismic response of reinforced concrete flat slab frames. After a summary of tests on connections, the paper examines tests carried out on frames with gra ...
Hybrid simulations were conducted to evaluate the system-level seismic response of a 4-story steel moment frame building and its gravity framing system through various levels of ground motion shaking. The experimental substructure examined in detail corres ...
Splicing of longitudinal reinforcement in the plastic hinge region of reinforced concrete (RC) members was common practice in buildings and bridges before the introduction of capacity design principles. Experimental and field observations showed that the p ...
Ambient vibration measurements and 3-D nonlinear time-history numerical modeling are used to assess the retrofitting measures conducted in a 6-story unreinforced masonry building (URM) built in the end of the 19th century in Switzerland. Retrofitting measu ...
This paper presents retrofit solutions for existing tall buildings by utilizing supplemental damping devices, namely oil dampers with relief valve (bilinear oil dampers). To this end, multiple retrofit schemes are presented for a benchmark 40-story steel m ...
The supports of out-of-plane loaded unreinforced masonry walls in buildings are subjected to a motion that is filtered and amplified by the building structure and, in some cases, can be significantly different from the ground motion. Moreover, because thes ...
Existing steel frame buildings in Switzerland that have been designed from the early 1970s typically utilized a steel lateral load resisting system with practically no seis- mic design requirements. However, Switzerland is a moderate seismicity zone and th ...
During the last two decades, thin concrete walls have been frequently used to brace mid- to high-rise buildings in some Latin American countries. This structural system differs significantly in terms of wall geometry and reinforcement layout from tradition ...