AVERTISSEMENT : Le chatbot Graph n'est pas programmé pour fournir des réponses explicites ou catégoriques à vos questions. Il transforme plutôt vos questions en demandes API qui sont distribuées aux différents services informatiques officiellement administrés par l'EPFL. Son but est uniquement de collecter et de recommander des références pertinentes à des contenus que vous pouvez explorer pour vous aider à répondre à vos questions.
There are three equivalent procedures to evaluate the voltages induced by lightning on power lines, namely, the Agrawal–Price–Gurbaxani model, the Taylor–Satterwhite–Harrison model, and the Rachidi model. The Cooray–Rubinstein approximation is a procedure ...
Recently, a simple and efficient method was proposed to take into account non-vertical risers at the end of transmission lines through an equivalent partial inductance. This paper evaluates the frequency above which the inductance needs to be taken into ac ...
The paper discusses specific frequency-domain properties of the electromagnetic time reversal (EMTR) method applied to locate faults and, more in general, disturbances in power networks. Specifically, we investigate the properties of two transfer functions ...
One of the main issues that has to be faced when evaluating lightning-induced overvoltages on a realistic network configuration is to implement the algorithm that solves the field-to-line coupling problem into an electromagnetic simulator that is able to r ...
This article discusses formulas for the surge/ characteristic impedance of vertical conductors. Calculated results of the surge impedance are compared with measured results on vertical conductors and transmission towers. The accuracy of the available time- ...
This paper presents the results of a pilot test performed on a real medium voltage distribution network in Switzerland with the aim of assessing the performance of a fault location system relying on the Electromagnetic Time Reversal (EMTR) method. To the b ...
This chapter describes two of the most adopted software tools for the evaluation of the lightning performance of transmission and distribution lines, namely FLASH and LIOV-EMTP (Lightning Induced OverVoltage - ElectroMagnetic Transient Program), together w ...
The Institution of Engineering and Technology IET2020
High-frequency electromagnetic fields such as those associated with electromagnetic pulse (EMP) and intentional electromagnetic interference (IEMI) can couple to overhead power lines. Since the height of the overhead power lines can be comparable or even l ...
The finite-difference time-domain method is one of the most widely used numerical electromagnetic computation techniques, and it has become an effective tool for analyzing electromagnetic transient phenomena in three-dimensional structures and grounding sy ...
Angle and amplitude estimation errors in magnetic direction finding, called site errors, are important sensor-specific errors in lightning location systems (LLS). They are known to be caused by nearby cables and overhead lines due to induced currents. Due ...