Multiphase transport and evaporative cooling in fuel cell gas diffusion layers
Publications associées (291)
Graph Chatbot
Chattez avec Graph Search
Posez n’importe quelle question sur les cours, conférences, exercices, recherches, actualités, etc. de l’EPFL ou essayez les exemples de questions ci-dessous.
AVERTISSEMENT : Le chatbot Graph n'est pas programmé pour fournir des réponses explicites ou catégoriques à vos questions. Il transforme plutôt vos questions en demandes API qui sont distribuées aux différents services informatiques officiellement administrés par l'EPFL. Son but est uniquement de collecter et de recommander des références pertinentes à des contenus que vous pouvez explorer pour vous aider à répondre à vos questions.
We use first-principles methods based on density functional perturbation theory to characterize the lifetimes of the acoustic phonon modes and their consequences on the thermal transport properties of graphene. We show that using a standard perturbative ap ...
Improving the energy efficiency of cooling systems can contribute to reduce the emission of greenhouse gases. Currently, most microelectronic applications are air-cooled. Switching to two-phase cooling systems would decrease power consumption and allow for ...
The Advanced Single-stage Planar Actuator (ASPA) is a nanometer-accurate magnetically levitated planar actuator with moving magnets. It is designed at the Eindhoven University of Technology in collaboration with an industrial partner active in the semicond ...
The contribution of this thesis is a thorough study of thermal aware policy design for MPSoCs. The study includes the modelling of their thermal behavior as well as the improvement and the definition of new thermal management and balancing policies. The wo ...
Directional solidification experiments on hypoperitectic Cu-Sn alloys have been performed at very low velocity in a high thermal gradient to ensure planar front growth of both phases. The diameter of the sample has been reduced to 500 mu m to strongly redu ...
A methodology is presented for estimating, at the city scale, the amount of biocide released from facades during rain events. The methodology consists of two elements. First, leaching of a single facade is simulated using a two-region model, one region for ...
Due to the increase in energy prices and spiralling consumption, there is a need to greatly reduce the cost of electricity within data centers, where it makes up 50% of the total cost of the IT infrastructure. A technological solution to this is using on-c ...
Thermal designers of data centers and server manufacturers are showing a greater concern regarding the cooling of the new generation data centers, which consume considerably more electricity and dissipate much more waste heat, a situation that is creating ...
The present report describes the work realized in the frame of a Mas- ter Pro ject in collaboration between the company EnBW Energie Baden- Württemberg AG (Germany) and the Section of Mechanical Engineering of the Swiss Institute of Technology of Lausanne ...
The analysis of cooling of a binary HTS 20 kA current lead (CL) operating between 4.5 and 300 K has been carried out. Assuming that the HTS module is conduction-cooled, two cooling options for the copper heat exchanger (HEX) part of the CL have been consid ...