Seismic Assessment and Retrofit of Pre-Northridge High Rise Steel Moment Resisting Frame Buildings with Bilinear Oil Dampers
Publications associées (34)
Graph Chatbot
Chattez avec Graph Search
Posez n’importe quelle question sur les cours, conférences, exercices, recherches, actualités, etc. de l’EPFL ou essayez les exemples de questions ci-dessous.
AVERTISSEMENT : Le chatbot Graph n'est pas programmé pour fournir des réponses explicites ou catégoriques à vos questions. Il transforme plutôt vos questions en demandes API qui sont distribuées aux différents services informatiques officiellement administrés par l'EPFL. Son but est uniquement de collecter et de recommander des références pertinentes à des contenus que vous pouvez explorer pour vous aider à répondre à vos questions.
Existing steel frame buildings in Switzerland that have been designed from the early 1970s typically utilized a steel lateral load resisting system with practically no seis- mic design requirements. However, Switzerland is a moderate seismicity zone and th ...
Nonlinear static and dynamic analysis is utilized by engineers to evaluate the seismic behavior of new and existing structures in the context of performance-based earthquake engineering. Numerous experiments on steel moment-resisting frames and their compo ...
With the advent of material science, high-performance steel materials have been developed for seismic applications that potentially reduce the earthquake-induced collapse risk of steel frame buildings. The High Yield Point (HYP400) steel is one of those ma ...
Steel lateral load-resisting systems offer a variety of design solutions to ensure a ductile behaviour of a structure during a seismic event, thereby achieving a relatively low earthquake-induced collapse risk, if designed and detailed properly according t ...
Centre suisse de la construction métallique (SZS)2019
The framework to evaluate the benefit of seismic upgrading of Galanis et al. (2018) is compared to that present in the Swiss seismic code for existing buildings since 2004, updated in 2017. To illustrate the comparison, the example building of Galanis et a ...
Hybrid simulations were conducted to evaluate the system-level seismic response of a 4-story steel moment frame building and its gravity framing system through various levels of ground motion shaking. The experimental substructure examined in detail corres ...
The Los Angeles Soft-Story Ordinance was enacted with the goal of reducing the collapse risk of woodframe buildings with soft, weak and open-front (SWOF) wall lines. Four alternative retrofit methods are permitted under the Ordinance including a SWOF-wall- ...
Nonlinear static and dynamic analyses are utilized by engineers for performance-based seismic risk evaluation of new and existing structures. In this context, nonlinear component modeling criteria are typically based on ASCE 41 guidelines. Experiments on w ...
Current simplified design methods for buildings with supplemental damping devices are mainly based on single-degreefreedom (SDF) shear-models. Common errors of such methods are attributed to the linearization of nonlinear damping and stiffness, higher buil ...
Inthecontextoflowtointermediateseismichazardregion,thisMasterprojectevaluate,thanks to a case study, the potential of friction dampers as retrofit solution of existing Concentrically Braced Frames (CBF). Simple to design and economic to build, they are comm ...