The transaortic valvular pressure gradient (TPG) plays a central role in decision-making for patients suffering from severe aortic stenosis. However, the flow-dependence nature of the TPG makes the diagnosis of aortic stenosis challenging since the markers of cardiac performance and afterload present high physiological interdependence and thus, isolated effects cannot be measured directly in vivo. We used a validated 1D mathematical model of the cardiovascular system, coupled with a model of aortic stenosis, to assess and quantify the independent effect of the main left ventricular performance parameters (end-systolic (E-es) and end-diastolic (E-ed) elastance) and principal afterload indices (total vascular resistance (TVR) and total arterial compliance (TAC)) on the TPG for different levels of aortic stenosis. In patients with critical aortic stenosis (aortic valve area (AVA)
Nikolaos Stergiopulos, Georgios Rovas, Vasiliki Bikia
Yves Perriard, Yoan René Cyrille Civet, Thomas Guillaume Martinez, Francesco Clavica, Armando Matthieu Walter, Silje Ekroll Jahren, Lorenzo Ferrari