Microscope à contraste de phasethumb|Photographie d'un cellule épithéliale de joue vue par un Microscope à contraste de phase Le microscope à contraste de phase est un microscope qui exploite les changements de phase d'une onde lumineuse traversant un échantillon. Cet instrument fut développé par le physicien hollandais Frederik Zernike dans les années 1930, ce qui lui valut le prix Nobel de physique en 1953. Emilie Bleeker, physicienne reconnue pour le développement d'instruments, est la première à mettre le microscope à contraste de phase en utilisation.
Third-generation sequencingThird-generation sequencing (also known as long-read sequencing) is a class of DNA sequencing methods currently under active development. Third generation sequencing technologies have the capability to produce substantially longer reads than second generation sequencing, also known as next-generation sequencing. Such an advantage has critical implications for both genome science and the study of biology in general. However, third generation sequencing data have much higher error rates than previous technologies, which can complicate downstream genome assembly and analysis of the resulting data.
Microscope à force atomiquethumb|350px|Le premier microscope à force atomique du monde, au musée de la Science de Londres. Le microscope à force atomique (AFM pour atomic force microscope) est un type de microscope à sonde locale permettant de visualiser la topographie de la surface d'un échantillon. Inventé en 1985, par Gerd Binnig, Calvin Quate et Christoph Gerber, ce type de microscopie repose essentiellement sur l'analyse d'un objet point par point au moyen d'un balayage via une sonde locale, assimilable à une pointe effilée.
Rapport signal sur bruitEn électronique, le rapport signal sur bruit (SNR, ) est le rapport des puissances entre la partie du signal qui représente une information et le reste, qui constitue un bruit de fond. Il est un indicateur de la qualité de la transmission d'une information. L'expression d'un rapport signal sur bruit se fonde implicitement sur le principe de superposition, qui pose que le signal total est la somme de ces composantes. Cette condition n'est vraie que si le phénomène concerné est linéaire.
Potentiel électrochimique de membraneToute cellule biologique est entourée d'une membrane dite membrane plasmique. Cette membrane est relativement imperméable aux espèces électriquement chargées telles que les ions et aux molécules qui peuvent participer à l'activité électrochimique (molécules polaires) telles que l'eau. Elle présente ainsi une grande résistance électrique et forme en quelque sorte un dipôle (comme un condensateur). Grâce à ces propriétés, la membrane sépare en deux compartiments étanches l'intérieur de la cellule, le cytoplasme, de l'extérieur de la cellule, le milieu extracellulaire.
Whole genome sequencingWhole genome sequencing (WGS), also known as full genome sequencing, complete genome sequencing, or entire genome sequencing, is the process of determining the entirety, or nearly the entirety, of the DNA sequence of an organism's genome at a single time. This entails sequencing all of an organism's chromosomal DNA as well as DNA contained in the mitochondria and, for plants, in the chloroplast. Whole genome sequencing has largely been used as a research tool, but was being introduced to clinics in 2014.
Membrane vesicle traffickingMembrane vesicle trafficking in eukaryotic animal cells involves movement of biochemical signal molecules from synthesis-and-packaging locations in the Golgi body to specific release locations on the inside of the plasma membrane of the secretory cell. It takes place in the form of Golgi membrane-bound micro-sized vesicles, termed membrane vesicles (MVs). In this process, the packed cellular products are released or secreted outside the cell, across its plasma membrane.
Cryomicroscopie électroniquevignette|Un microscope électronique en transmission (2003). La cryomicroscopie électronique (cryo-ME) correspond à une technique particulière de préparation d’échantillons biologiques utilisée en microscopie électronique en transmission. Développée au début des années 1980, cette technique permet de réduire les dommages d’irradiation causés par le faisceau d’électrons. Elle permet également de préserver la morphologie et la structure des échantillons.
Microscope électroniquethumb|Microscope électronique construit par Ernst Ruska en 1933.thumb|Collection de microscopes électroniques anciens (National Museum of Health & Medicine). Un microscope électronique (ME) est un type de microscope qui utilise un faisceau d'électrons pour illuminer un échantillon et en créer une très agrandie. Il est inventé en 1931 par des ingénieurs allemands. Les microscopes électroniques ont un pouvoir de résolution supérieur aux microscopes optiques qui utilisent des rayonnements électromagnétiques visibles.
Biologie cellulairethumb|Détection de filaments d'actine dans des cellules animales (immunofluorescence) La biologie cellulaire (anciennement appelée cytologie) est une discipline scientifique qui étudie les cellules, du point de vue structural et fonctionnel, et les utilise pour des applications en biotechnologie. Elle s'intéresse à l'écosystème cellulaire, c'est-à-dire à l'équilibre dynamique et autorégulé des fonctions cellulaires, dans un contexte normal ou perturbé.