Electron ionizationElectron ionization (EI, formerly known as electron impact ionization and electron bombardment ionization) is an ionization method in which energetic electrons interact with solid or gas phase atoms or molecules to produce ions. EI was one of the first ionization techniques developed for mass spectrometry. However, this method is still a popular ionization technique. This technique is considered a hard (high fragmentation) ionization method, since it uses highly energetic electrons to produce ions.
Hydrodynamic voltammetryIn analytical chemistry, hydrodynamic voltammetry is a form of voltammetry in which the analyte solution flows relative to a working electrode. In many voltammetry techniques, the solution is intentionally left still to allow diffusion-controlled mass transfer. When a solution is made to flow, through stirring or some other physical mechanism, it is very important to the technique to achieve a very controlled flux or mass transfer in order to obtain predictable results.
Potentiel de reposLe potentiel de repos membranaire (RMP, pour l'anglais resting membrane potential) est le potentiel électrochimique de membrane de la membrane plasmique d'une cellule excitable lorsqu'elle est au repos ; c'est un des états possibles du potentiel de la membrane. En introduisant une électrode de mesure à l'intérieur de la cellule (voir la méthode de patch-clamp), on constate une différence de potentiel : la face interne de la membrane est négative par rapport à une électrode de référence placée sur la face externe de la membrane.
Cinétique chimiqueLa cinétique chimique est l'étude de la vitesse des réactions chimiques. Sur le plan disciplinaire, elle fait partie de la chimie physique. Certaines réactions sont totales et très rapides, voire instantanées, comme les explosions. D'autres sont tellement lentes qu'elles durent plusieurs années (comme la formation de la rouille), voire plusieurs siècles (comme la formation du charbon ou du pétrole). Certaines sont même tellement lentes que les réactifs de départ sont considérés comme stables, par exemple la transformation du diamant en carbone graphite.
AnodeL'anode d'un appareil passif parcouru par un courant continu est l'électrode où, en sens conventionnel, entre le courant (en courant électronique, l'électrode d'où sortent les électrons). Par exemple, pour une diode, c'est l'électrode reliée au pôle positif du générateur ; pour une pile électrique faisant office de générateur, c'est l'électrode négative. Dans une électrolyse active en chimie, avec fourniture d'énergie électrique, l'anode est par définition là où sont contraints (par le champ électrique) de se diriger les ions négatifs ou anions.
Selected-ion flow-tube mass spectrometrySelected-ion flow-tube mass spectrometry (SIFT-MS) is a quantitative mass spectrometry technique for trace gas analysis which involves the chemical ionization of trace volatile compounds by selected positive precursor ions during a well-defined time period along a flow tube. Absolute concentrations of trace compounds present in air, breath or the headspace of bottled liquid samples can be calculated in real time from the ratio of the precursor and product ion signal ratios, without the need for sample preparation or calibration with standard mixtures.
Simulation informatiquevignette|upright=1|Une simulation informatique, sur une étendue de , de l'évolution du typhon Mawar produite par le Modèle météorologique Weather Research and Forecasting La simulation informatique ou numérique est l'exécution d'un programme informatique sur un ordinateur ou réseau en vue de simuler un phénomène physique réel et complexe (par exemple : chute d’un corps sur un support mou, résistance d’une plateforme pétrolière à la houle, fatigue d’un matériau sous sollicitation vibratoire, usure d’un roulem
Effet isotopique cinétiqueL'effet isotopique cinétique (en anglais, kinetic isotope effect ou KIE) est la variation de la vitesse d'une réaction chimique lorsqu'un atome d'un des réactifs est remplacé par l'un de ses isotopes. Par exemple, le remplacement d'un atome C par un atome C conduit à un effet isotopique cinétique défini par le rapport des constantes de vitesse (on met en général au numérateur la constante qui concerne l'isotope le plus léger). Dans la substitution nucléophile du bromure de méthyle par l'ion cyanure, le rapport mesuré est de .
Potentiel électrochimique de membraneToute cellule biologique est entourée d'une membrane dite membrane plasmique. Cette membrane est relativement imperméable aux espèces électriquement chargées telles que les ions et aux molécules qui peuvent participer à l'activité électrochimique (molécules polaires) telles que l'eau. Elle présente ainsi une grande résistance électrique et forme en quelque sorte un dipôle (comme un condensateur). Grâce à ces propriétés, la membrane sépare en deux compartiments étanches l'intérieur de la cellule, le cytoplasme, de l'extérieur de la cellule, le milieu extracellulaire.
Standard electrode potentialIn electrochemistry, standard electrode potential , or , is a measure of the reducing power of any element or compound. The IUPAC "Gold Book" defines it as: "the value of the standard emf (electromotive force) of a cell in which molecular hydrogen under standard pressure is oxidized to solvated protons at the left-hand electrode". The basis for an electrochemical cell, such as the galvanic cell, is always a redox reaction which can be broken down into two half-reactions: oxidation at anode (loss of electron) and reduction at cathode (gain of electron).